Heated Oxygen Sensor Installation
INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2)
INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Heated Oxygen Sensor -- Installation |
1. INSTALL HEATED OXYGEN SENSOR (for Bank 2 Sensor 2) |
Using SST, install the sensor to the front exhaust pipe.
- SST
- 09224-00010
- Torque:
- 40 N*m{408 kgf*cm, 30 ft.*lbf} for use with SST
- 44 N*m{449 kgf*cm, 32 ft.*lbf} for use without SST
- HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).
Connect the sensor connector.
2. INSTALL HEATED OXYGEN SENSOR (for Bank 1 Sensor 2) |
Using SST, install the sensor to the front exhaust pipe.
- SST
- 09224-00010
- Torque:
- 40 N*m{408 kgf*cm, 30 ft.*lbf} for use with SST
- 44 N*m{449 kgf*cm, 32 ft.*lbf} for use without SST
- HINT:
- Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).
Connect the sensor connector.
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |