Canister -- Inspection |
1. INSPECT CANISTER |
![]() |
Inspect the operation of the canister.
- STANDARD:
Checking Method Specified Condition Close port B and C, then apply vacuum to port A No leak Close port C, then blow air into port A Air flows from port B Blow air into port A Air flows from both port B and C