Power Window Control System (For Models With Jam Protection Function On 4 Windows) - Jam Protection Function Does Not Operate
DESCRIPTION
INSPECTION PROCEDURE
PERFORM INITIALIZATION
CHECK JAM PROTECTION FUNCTION OPERATING RANGE
POWER WINDOW CONTROL SYSTEM (for Models with Jam Protection Function on 4 Windows) - Jam Protection Function does not Operate
DESCRIPTION
This symptom may occur to all door windows.
The jam protection function operates within a specified range during the manual up or auto up operation.
INSPECTION PROCEDURE
Initialize the power window regulator motor ().
Check if the power window auto up/down function operates ().
- OK:
- Auto up/down function operates.
| END (PROBLEM DUE TO INITIALIZATION FAILURE) |
|
|
2.CHECK JAM PROTECTION FUNCTION OPERATING RANGE |
Check if the jam protection function operates for applicable power window.
- The jam protection function does not operate from the fully closed position of the door glass to 4 mm (0.157 in.) below that.
- OK:
- Jam protection function operates.
ResultResult | Proceed to |
OK | A |
NG (Front LH side power window) | B |
NG (Front RH side power window) | C |
NG (Rear power window LH) | D |
NG (Rear power window RH) | E |
| REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH ()
|
|
|
| REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH ()
|
|
|
| REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH ()
|
|
|
| REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH ()
|
|
|