Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
REMOVE AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)
REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)
REMOVE BLOWER MOTOR CONTROL (for Automatic Air Conditioning System)
Blower Unit -- Disassembly |
1. REMOVE AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System) |
![]() |
Detach the 3 claws and remove the air inlet damper control cable sub-assembly.
2. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System) |
Detach the claw and remove the lever.
Text in Illustration *1 Lever
![]() |
Remove the 3 screws and recirculation damper servo sub-assembly.
![]() |
3. REMOVE CLEAN AIR FILTER |
![]() |
Detach the claw and remove the air filter case.
Remove the clean air filter.
4. REMOVE BLOWER RESISTOR (for Manual Air Conditioning System) |
![]() |
Disconnect the connector.
Remove the 2 screws and blower resistor.
5. REMOVE BLOWER MOTOR CONTROL (for Automatic Air Conditioning System) |
![]() |
Disconnect the connector.
Remove the 2 screws and blower motor control.
6. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY |
![]() |
Detach the clamp and disconnect the connector.
Remove the 3 screws and blower motor with fan sub-assembly.