Air Conditioning System Plasmacluster Circuit

Air Conditioning. Camry. Acv40 Gsv40

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT AIR CONDITIONING AMPLIFIER

CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)

CHECK HARNESS AND CONNECTOR (ION GENERATOR - BATTERY)

CHECK HARNESS AND CONNECTOR (ION GENERATOR - A/C AMPLIFIER)

AIR CONDITIONING SYSTEM - Plasmacluster Circuit


DESCRIPTION

The plasmacluster operates in conjunction with blower switch operation. The plasmacluster operation indicator (CLEAN, ION) illuminates on the A/C control assembly when the plasmacluster is operating. When the plasmacluster is operating, the operation mode automatically switches between the sterilization mode (CLEAN) and the negative ion mode (ION) every 15 minutes.

WIRING DIAGRAM


Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit


INSPECTION PROCEDURE

1.INSPECT AIR CONDITIONING AMPLIFIER


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit
  1. Remove the A/C amplifier with the connectors still connected.

  1. Turn the ignition switch to the ON position.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    CLEAN mode:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    E38-39 (PCD1) - Body ground
    Ignition switch: ON
    Blower switch: OFF
    10 to 14 V
    E38-39 (PCD1) - Body ground
    Ignition switch: ON
    Blower switch: ON
    Below 1 V
    ION Mode:
    Tester Connection (Symbols)
    Condition
    Specified Condition
    E38-40 (PCD2) - Body ground
    Ignition switch: ON
    Blower switch: OFF
    10 to 14 V
    E38-40 (PCD2) - Body ground
    Ignition switch: ON
    Blower switch: ON
    Below 1 V


NG
Go to step 2
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

2.CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit
  1. Disconnect the connector from the ion generator.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    (Symbols)
    Condition
    Specified Condition
    E12-5 (GND) - Body ground
    Always
    Below 1 Ω


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (ION GENERATOR - BATTERY)


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    (Symbols)
    Condition
    Specified Condition
    E12-2 (IG) - Body ground
    Ignition switch: LOCK
    Below 1 V
    E12-2 (IG) - Body ground
    Ignition switch: ON
    10 to 14 V


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (ION GENERATOR - A/C AMPLIFIER)


    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit
  1. Disconnect the connector from the A/C amplifier.



    Camry. Acv40 Gsv40.Air Conditioning.Air Conditioning System.Air Conditioning System  Plasmacluster Circuit
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    (Symbols)
    Condition
    Specified Condition
    E12-4 (PCL) - E38-39 (PCD1)
    Always
    Below 1 Ω
    E12-4 (PCL) - Body ground
    Always
    10 kΩ or higher
    E12-3 (ION-) - E38-40 (PCD2)
    Always
    Below 1 Ω
    E12-3 (ION-) - Body ground
    Always
    10 kΩ or higher


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ION GENERATOR