Meter / Gauge System Odo/Trip Switch Malfunction
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (ODO/TRIP CHANGE SW)
INSPECT TRIP SWITCH
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
METER / GAUGE SYSTEM - Odo/Trip Switch Malfunction |
DESCRIPTION
The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.- HINT:
- The whole light control rheostat should be replaced if the ODO/TRIP switch is malfunctioning.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (ODO/TRIP CHANGE SW) |
Using the GTS, read the Data List (LandCruiser RM0000012G70JTX.html).
Combination MeterTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
ODO/TRIP Change SW
| ODO/TRIP change switch/OFF or ON
| OFF: ODO/TRIP change switch released
| -
|
ON: ODO/TRIP change switch pressed
|
- OK:
- The value displayed on the GTS changes with the actual ODO/TRIP change switch operation.
Disconnect the G16 trip switch connector.
Inspect the ODO/TRIP switch
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Switch Condition
| Specified Condition
|
4 (A/B) - 1 (E)
| ODO/TRIP switch on (pushed)
| Below 1 Ω
|
ODO/TRIP switch off (Not pushed)
| 1 MΩ or higher
|
for RHDTester Connection
| Switch Condition
| Specified Condition
|
1 (A/B) - 4 (E)
| ODO/TRIP switch on (pushed)
| Below 1 Ω
|
ODO/TRIP switch off (Not pushed)
| 1 MΩ or higher
|
3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH) |
Disconnect the G6 combination meter assembly connector.
Disconnect the G16 trip switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Condition
| Specified Condition
|
G6-11 (RSET) - G16-4 (A/B)
| Always
| Below 1 Ω
|
G6-11 (RSET) - Body ground
| Always
| 10 kΩ or higher
|
for RHDTester Connection
| Condition
| Specified Condition
|
G6-11 (RSET) - G16-1 (A/B)
| Always
| Below 1 Ω
|
G6-11 (RSET) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|