Meter / Gauge System Entire Combination Meter Does Not Operate
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
METER / GAUGE SYSTEM - Entire Combination Meter does not Operate |
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when turn the ignition switch to ON, the indicator will not operate.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND) |
Disconnect the combination meter assembly connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
G6-21 (E2) - Body ground
| Always
| Below 1 Ω
|
G6-1 (EP) - Body ground
| Always
| Below 1 Ω
|
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
G6-28 (IG+) - Body ground
| Ignition switch ON
| 11 to 14 V
|
G6-26 (B) - Body ground
| Always
| 11 to 14 V
|
Text in Illustration*a
| Front view of wire harness connector (to Combination Meter Assembly
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|