Meter / Gauge System Operating Light Control Rheostat Does Not Change Light Brightness
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (TAIL CANCEL SW, RHEOSTAT VALUE)
INSPECT TRIP SWITCH (LIGHT CONTROL RHEOSTAT)
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH [LIGHT CONTROL RHEOSTAT])
CHECK COMBINATION METER ASSEMBLY
METER / GAUGE SYSTEM - Operating Light Control Rheostat does not Change Light Brightness |
DESCRIPTION
When the light control rheostat knob is turned right, the combination meter and vehicle interior illumination will become brighter. When the light control rheostat knob is turned left, the combination meter and vehicle illumination will dim.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (TAIL CANCEL SW, RHEOSTAT VALUE) |
Using the GTS, read the Data List (LandCruiser RM0000012G70JTX.html).
Combination MeterTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Tail Cancel SW*
| Tail cancel switch/OFF or ON
| OFF: Tail cancel switch off
| -
|
ON: Tail cancel switch on
|
Rheostat value
| Light control rheostat switch input/Min.: 0, Max.: 100
| Light control rheostat switch is fully turned right (0) → fully turned left (100)
| Unit: %
|
- *: w/ TAIL Cancel Switch
- OK:
- Light brightness can be changed within specified range by manual operation.
2.INSPECT TRIP SWITCH (LIGHT CONTROL RHEOSTAT) |
Inspect the light control rheostat. (w/o TAIL Cancel Switch)
Remove the light control rheostat (LandCruiser RM000003QKY01DX.html).
Measure the resistance according to the table below.
- Standard Resistance:
for LHDTester Connection
| Switch Condition
| Specified Condition
|
5 (T) - 1 (E)
| Always
| 8 to 12 kΩ
|
7 (RV) - 1 (E)
| Light control rheostat fully turned right → fully turned left
| Below 100 Ω → 8 to 12 kΩ
|
for RHDTester Connection
| Switch Condition
| Specified Condition
|
8 (T) - 4 (E)
| Always
| 8 to 12 kΩ
|
6 (RV) - 4 (E)
| Light control rheostat fully turned right → fully turned left
| Below 100 Ω → 8 to 12 kΩ
|
Inspect the light control rheostat. (w/ TAIL Cancel Switch)
Remove the light control rheostat (LandCruiser RM000003QKY01DX.html).
Measure the resistance according to the table below.
- Standard Resistance:
for LHDTester Connection
| Switch Condition
| Specified Condition
|
5 (T) - 6 (TC)
| TAIL cancel switch off → on
| 1 MΩ or higher → Below 1 Ω
|
5 (T) - 1 (E)
| Always
| 8 to 12 kΩ
|
7 (RV) - 1 (E)
| Light control rheostat fully turned right → fully turned left
| Below 100 Ω → 8 to 12 kΩ
|
for RHDTester Connection
| Switch Condition
| Specified Condition
|
8 (T) - 7 (TC)
| TAIL cancel switch off → on
| 1 MΩ or higher → Below 1 Ω
|
8 (T) - 4 (E)
| Always
| 8 to 12 kΩ
|
6 (RV) - 4 (E)
| Light control rheostat fully turned right → fully turned left
| Below 100 Ω → 8 to 12 kΩ
|
3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH [LIGHT CONTROL RHEOSTAT]) |
Disconnect the G6 combination meter assembly connector.
Disconnect the G16 trip switch (light control rheostat) connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Condition
| Specified Condition
|
G6-10 (TC) - G16-6 (TC)*
| Always
| Below 1 Ω
|
G6-6 (SW1) - G16-5 (T)
| Always
| Below 1 Ω
|
G6-7 (SW2) - G16-7 (RV)
| Always
| Below 1 Ω
|
G6-22 (SW3) - G16-1 (E)
| Always
| Below 1 Ω
|
for RHDTester Connection
| Condition
| Specified Condition
|
G6-10 (TC) - G16-7 (TC)*
| Always
| Below 1 Ω
|
G6-6 (SW1) - G16-8 (T)
| Always
| Below 1 Ω
|
G6-7 (SW2) - G16-6 (RV)
| Always
| Below 1 Ω
|
G6-22 (SW3) - G16-4 (E)
| Always
| Below 1 Ω
|
G6-22 (SW3) - G16-4 (E)
| Always
| Below 1 Ω
|
- *: w/ TAIL Cancel Switch
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.CHECK COMBINATION METER ASSEMBLY |
Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.
- OK:
- Combination meter assembly operates normally.
OK |
|
|
|
END (COMBINATION METER ASSEMBLY IS DEFECTIVE) |
|