Dtc C1831/31 Accumulator Solenoid Malfunction / Upside
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ACCUMULATOR VALVE)
RECONFIRM DTC
CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - STABILIZER CONTROL SOLENOID VALVE)
INSPECT STABILIZER CONTROL SOLENOID VALVE
DTC C1831/31 Accumulator Solenoid Malfunction / Upside |
DTC C1832/32 Accumulator Solenoid Malfunction / Downside |
DESCRIPTION
The stabilizer control ECU receives information from the steering angle sensor, skid control ECU (speed signal) and yaw rate and acceleration sensor via CAN communication. Based on this information, the stabilizer control ECU turns the stabilizer control solenoid valve (built into the stabilizer control with accumulator housing assembly) on or off.DTC Code
| DTC Detection Condition
| Trouble Area
|
C1831/31 C1832/32
| Either condition is met:
- An open circuit signal is detected for a second continuously when current is not applied to the solenoid valve.
- A short circuit signal is detected 8 seconds continuously when current is applied to the solenoid valve.
| - Harness or connector
- Stabilizer control solenoid valve (Stabilizer control with accumulator housing assembly)
- Stabilizer control ECU
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING INTELLIGENT TESTER (ACCUMULATOR VALVE) |
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Chassis / KDSS / Data List.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
KDSSTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Accumulator Valve (Downside)
| Stabilizer control solenoid valve (for Lower Chamber)/ ON or OFF
| ON: Stabilizer control solenoid valve closed OFF: Stabilizer control solenoid valve open
| -
|
Accumulator Valve (Upside)
| Stabilizer control solenoid valve (for Upper Chamber)/ ON or OFF
| ON: Stabilizer control solenoid valve open OFF: Stabilizer control solenoid valve closed
| -
|
Perform the Active Test of the stabilizer control ECU using the intelligent tester.
KDSSTester Display
| Test Part
| Control Range
| Diagnostic Note
|
Accumulator Valve (Upside)
| Stabilizer control solenoid valve (for Upper Chamber)
| Valve ON / OFF
| The operating sound of the solenoid (clicking sound) can be heard ON: Data List ON OFF: Data List OFF When the Active Test is performed, the solenoid turns on for 3 seconds.
|
Accumulator Valve (Downside)
| Stabilizer control solenoid valve (for Lower Chamber)
| Valve ON / OFF
| The operating sound of the solenoid (clicking sound) can be heard ON: Data List ON OFF: Data List OFF When the Active Test is performed, the solenoid turns on for 3 seconds.
|
Check that the solenoid operating sound can be heard, and that the Data List display changes between ON and OFF in response to the Active Test.
- OK:
- Solenoid operating sound can be heard and display changes between ON and OFF in response to Active Test.
Clear the DTCs (LandCruiser RM000001N9I01KX.html)
Check for DTCs (LandCruiser RM000001N9I01KX.html).
ResultResult
| Proceed to
|
DTC is output
| A
|
DTC is not output
| B
|
3.CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - STABILIZER CONTROL SOLENOID VALVE) |
Disconnect the stabilizer control ECU connector.
Disconnect the Stabilizer control with accumulator housing assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
G123-3 (SLAU) - R20-6 (SLAU)
| Always
| Below 1 Ω
|
G123-3 (SLAU) - Body ground
| Always
| 10 kΩ or higher
|
G123-1 (SLAL) - R20-5 (SLAL)
| Always
| Below 1 Ω
|
G123-1 (SLAL) - Body ground
| Always
| 10 kΩ or higher
|
R20-4 (AUG) - Body ground
| Always
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.INSPECT STABILIZER CONTROL SOLENOID VALVE |
Disconnect the Stabilizer control with accumulator housing assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
C1831/31 (for Upper Chamber)Tester Connection
| Condition
| Specified Condition
|
5 (SLAL) - 4 (AUG)
| 25°C (77°F)
| 24.3 to 25.7 Ω
|
C1832/32 (for Lower Chamber)Tester Connection
| Condition
| Specified Condition
|
6 (SLAU) - 4 (AUG)
| 25°C (77°F)
| 24.3 to 25.7 Ω
|
Text in Illustration*a
| Component without harness connected (Stabilizer Control with Accumulator Housing Assembly)
|
Check for an operating sound of the stabilizer control solenoid valve.
for Upper Chamber:
Connect terminal 5 (SLAL) to the positive (+) battery terminal, and terminal 4 (AUG) to the negative (-) battery terminal.
- OK:
- An operating sound (click sound) can be heard.
Text in Illustration*a
| Component without harness connected (Stabilizer Control with Accumulator Housing Assembly)
|
for Lower Chamber:
Connect terminal 6 (SLAU) to the positive (+) battery terminal, and terminal 4 (AUG) to the negative (-) battery terminal.
- OK:
- An operating sound (click sound) can be heard.
Text in Illustration*a
| Component without harness connected (Stabilizer Control with Accumulator Housing Assembly)
|