Dtc P2716 Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)

Drivetrain. Corolla. Zre142 Aze141

DESCRIPTION

MONITOR DESCRIPTION

MONITOR STRATEGY

TYPICAL ENABLING CONDITIONS

TYPICAL MALFUNCTION THRESHOLDS

COMPONENT OPERATING RANGE

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SLT)

CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

INSPECT SHIFT SOLENOID VALVE SLT

DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)


DESCRIPTION

Refer to the system description for DTC P2714 (Link).

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detecting logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1.0 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor runs whenever the following DTCs are not present
None
Solenoid current cut status
Not cut
Battery voltage
11 V or more
Target duty cycle
19 % or more
Ignition switch
ON
Starter
OFF

TYPICAL MALFUNCTION THRESHOLDS


Solenoid voltage monitor (SLT) from MIC
No signal

COMPONENT OPERATING RANGE


Shift solenoid valve SLT
Resistance: 5.0 Ω to 5.6 Ω at 20°C (68°F)

WIRING DIAGRAM


Corolla. Zre142 Aze141.U341E Automatic Transmission Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (COROLLA_ZRE142 RM000000W770S5X.html).
1.INSPECT TRANSMISSION WIRE (SLT)


    Corolla. Zre142 Aze141.U341E Automatic Transmission Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
  1. Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (SLT+) - 8 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    3 (SLT+) - Body ground
    Always
    10 kΩ or higher
    8 (SLT-) - Body ground
    Always



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    Corolla. Zre142 Aze141.U341E Automatic Transmission Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
  1. Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connectors.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B31-61 (SLT+) - B31-60 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    B31-61 (SLT+) - Body ground
    Always
    10 kΩ or higher
    B31-60 (SLT-) - Body ground
    Always



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2ZR-FE) (COROLLA_ZRE142 RM000001CN0030X.html)

3.INSPECT SHIFT SOLENOID VALVE SLT


    Corolla. Zre142 Aze141.U341E Automatic Transmission Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance :
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω
  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.


NG
REPLACE SHIFT SOLENOID VALVE SLT (COROLLA_ZRE142 RM00000193102IX.html)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (COROLLA_ZRE142 RM00000191I02NX.html)