Heated Oxygen Sensor Inspection

Двигатель. Toyota Rav4. Aca30, 33, 38 Ala30

  1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)

Heated Oxygen Sensor -- Inspection



1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 2)


    Toyota Rav4. Aca30, 33, 38 Ala30.Система Снижения Токсичности Отработавших Газов Двигателя 2Az-Fe.Система Снижения Токсичности Отработавших Газов.Heated Oxygen Sensor  Inspection
  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT1B) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT1B) - 4 (E2)
    10 kΩ or higher
    If the resistance is not as specified, replace the sensor.