Ig1 Relay On-Vehicle Inspection
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
REMOVE IG1 RELAY
INSPECT RELAY
INSTALL IG1 RELAY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Ig1 Relay -- On-Vehicle Inspection |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- ПРЕДОСТЕРЕЖЕНИЕ:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
Remove the IG1 relay from the instrument panel junction block.
Measure resistance of the IG1 relay.
- Standard resistance:
Tester Connection
| Specified Condition
|
3 - 5
| 10 kΩ or higher
|
3 - 5
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
|
If the result is not as specified, replace the relay.
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |