Circuit Opening Relay On-Vehicle Inspection
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
INSPECT INSTRUMENT PANEL JUNCTION BLOCK
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Circuit Opening Relay -- On-Vehicle Inspection |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- ПРЕДОСТЕРЕЖЕНИЕ:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
2. INSPECT INSTRUMENT PANEL JUNCTION BLOCK |
- ПРИМЕЧАНИЕ:
- The circuit opening relay is built into the instrument panel junction block.
Measure the resistance between the terminals.
- Standard resistance:
Tester Connection
| Specified Condition
|
1B-11 - 1A-8
| 10 kΩ or higher
|
1B-11 - 1A-8
| Below 1 Ω (when battery voltage is applied to terminals 1E-5 and 1D-1)
|
If the result is not as specified, replace the instrument panel junction block.
3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |