Свеча Накаливания Проверка Без Снятия С Автомобиля
INSPECT GLOW PLUG
Свеча Накаливания -- Проверка Без Снятия С Автомобиля |
- ПРИМЕЧАНИЕ:
- Turn the ignition switch off for 60 seconds before performing this inspection.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Glow plug terminal - Body ground
| 20°C (68°F)
| Approximately 1.0 Ω
|
- ПРИМЕЧАНИЕ:
- Do not damage the glow plug pipes as doing so could cause an open circuit or shorten the life of the glow plugs.
- Prevent oil and gasoline from contacting the glow plugs when cleaning them.
- During the inspection, be sure to wipe off any oil on the terminal and Bakelite washer with a dry cloth.
- Do not apply more than 11 V to the glow plug as it could cause an open circuit.