Двигатель. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Система Управления Двигателем 2Zr-Fe. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Ecm -- Установка |
1. INSTALL ECM |
Install the bracket to the ECM with the 4 screws.
- Момент затяжки:
- 3.0 Н*м{30 кгс*см, 27 фунт-сила-дюймов}
![]() |
Install the ECM with the 2 bolts.
- Момент затяжки:
- 8.0 Н*м{82 кгс*см, 71 фунт-сила-дюймов}
![]() |
Connect the 2 ECM connectors.
Connect the 2 ECM connectors and lower the 2 levers.
- ПРИМЕЧАНИЕ:
- When connecting the connectors, make sure that dirt, water or other foreign matter does not get caught between the connectors and other parts.
- Make sure that the 2 levers are securely lowered.
2. INSTALL AIR CLEANER CASE |
Install the air cleaner case with the 3 bolts.
- Момент затяжки:
- 7.0 Н*м{71 кгс*см, 62 фунт-сила-дюймов}
![]() |
Install the wire harness clamp to the air cleaner case.
Install the air cleaner filter element.
3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
Connect the air cleaner cap sub-assembly with the band.
![]() |
Connect the ventilation hose.
Connect the 2 clamps.
![]() |
Connect the mass air flow meter connector.
4. INSTALL NO. 2 CYLINDER HEAD COVER |
Engage the 4 clips to install the V-bank cover.
- ПРИМЕЧАНИЕ:
- Be sure to engage the clips securely.
- Do not apply excessive force or do not hit the cover to engage the clips. This may cause the cover to break.
![]() |
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
6. REGISTER IMMOBILISER COMMUNICATION ID |
- ПРИМЕЧАНИЕ:
- If the ECM is replaced, register the ECM communication ID for Immobiliser System (Refer to the Service Bulletin for Registration).
7. PERFORM INITIALIZATION (for U341E) |
- УКАЗАНИЕ:
- If the ECM is replaced, certain procedures are necessary (See page Нажмите здесь).