Двигатель. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Система Охлаждения 2Ad-Fhv. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Радиатор -- Проверка Без Снятия С Автомобиля |
1. INSPECT RADIATOR RESERVOIR CAP SUB-ASSEMBLY |
Measure the valve opening pressure.
If there are water stains or foreign matter on O-ring 1, clean it with water and finger scouring.
Check that O-ring 1 is not deformed, cracked or swollen.
Apply engine coolant to O-ring 1 and rubber packing 2 before using a radiator cap tester.
When using the cap tester, tilt it more than 30°.
Pump the cap tester several times, and check the maximum pressure*.
- Pump speed:
- 1 pump per second
- УКАЗАНИЕ:
- *: Even if the cap cannot maintain the maximum pressure, it is not a defect.
- Judgment criterion:
Item Specified Condition Standard value
(for brand-new cap)93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) Minimum standard value
(for used cap)78.5 kPa (0.8 kgf/cm2, 11.4 psi)
![]() |
2. INSPECT RADIATOR ASSEMBLY |
![]() |
Check that the radiator, condenser and intercooler are not blocked with leaves, dirt, or insects. Clean the hose connections.
If the fins are blocked, wash them with water or a steam cleaner.- ПРИМЕЧАНИЕ:
- If the distance between the steam cleaner and core is too close, the fins may be damaged.
- When cleaning the intercooler, make sure no water enters its interior.
- Keep the following injection distance.
- Standard injection distance:
Injection Pressure Specified Condition 2942 to 4903 kPa
(30 to 50 kgf/cm2, 427 to 711 psi)300 mm (11.81 in.) 4903 to 7845 kPa
(50 to 80 kgf/cm2, 711 to 1.138 psi)500 mm (19.69 in.)
- If the fins are bent, straighten them with a screwdriver or pliers.
- Never apply water directly onto the electronic components.
Dry the fins with compressed air.