Двигатель. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Топливная Система 1Nd-Tv. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Нагнетающий Топливный Насос -- Проверка |
1. INSPECT SUPPLY PUMP ASSEMBLY |
![]() |
Check the resistance of the fuel metering unit.
Using an ohmmeter, measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 2.60 to 3.15 Ω
Check the resistance of the fuel temperature sensor.
Using an ohmmeter, measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Condition Specified Condition 1 - 2 -20°C (-4°F) 13.92 to 17.01 Ω 1 - 2 0°C (32°F) 5.31 to 6.49 Ω 1 - 2 20°C (68°F) 2.25 to 2.75 Ω 1 - 2 40°C (104°F) 1.06 to 1.29 Ω 1 - 2 60°C (140°F) 0.54 to 0.66 Ω 1 - 2 80°C (176°F) 0.29 to 0.36 Ω 1 - 2 100°C (212°F) 0.17 to 0.20 Ω