Двигатель. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Система Охлаждения 2Zr-Fe. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Радиатор -- Проверка Без Снятия С Автомобиля |
1. CHECK RESERVE TANK CAP |
![]() |
Measure the valve opening pressure.
If there are water stains or foreign matter on O-ring 1, clean it with water and finger scouring.
Check that O-ring 1 is not deformed, cracked or swollen.
Apply engine coolant to O-ring 1 and rubber packing 2 before using the radiator cap tester.
When using the cap tester, tilt it to more than 30 degrees.
Pump the cap tester several times, and check the maximum pressure *1.
- Pumping speed:
- 1 pump per second
- УКАЗАНИЕ:
- *1: Even if the cap cannot maintain the maximum pressure, it is not a defect.
- Judgment Criterion:
Item Specified Condition Standard value
(for brand-new cap)93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi) Minimum standard value
(for used cap)78.5 kPa (0.8 kgf/cm2, 1138 psi)
2. INSPECT FINS FOR BLOCKAGE |
![]() |
If the fins are clogged, wash them with water or a steam cleaner and dry them with compressed air.
- ПРИМЕЧАНИЕ:
- To avoid damaging the fins, the injection direction should be at right angles to the core surface.
- If the steam cleaner is too close to the core, there is a possibility of damaging the fins, so keep the following injection distances.
- Standard injection distance:
Injection Pressure Specified Condition 2942 to 4903 kPa
(30 to 50 kgf/cm2, 427 to 711 psi)300 mm (11.81 in.) 4903 to 7845 kPa
(50 to 80 kgf/cm2, 711 to 1,138 psi)500 mm (19.69 in.)
- If the fins are bent, straighten them with a screwdriver or pliers.
- Do not expose electronic components to water.