Air Conditioning System (For Manual Air Conditioning System) - Blower Motor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (BLOWER MOTOR)
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR - BATTERY AND BODY GROUND)
CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR - AIR CONDITIONING AMPLIFIER)
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY
CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY
AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) - Blower Motor Circuit
DESCRIPTION

The blower with fan motor sub-assembly operates according to signals from the air conditioning amplifier assembly. The blower with fan motor sub-assembly speed signals are transmitted by changes in the duty ratio.
Duty Ratio:
The duty ratio is the ratio of the blower with fan motor sub-assembly on time (T1) to the total of the blower with fan motor sub-assembly on and off time (T2).
The air conditioning amplifier assembly controls the blower with fan motor sub-assembly speed.
WIRING DIAGRAM

INSPECTION PROCEDURE
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (BLOWER MOTOR) |
Select the Active Test, use the intelligent tester to generate a control command, and then check that the blower with fan motor sub-assembly operates ().
Air ConditionerTester Display | Test Part | Control Range | Diagnostic Note |
Blower Motor |
Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
- OK:
- Blower with fan motor sub-assembly operates and blower with fan motor sub-assembly speed changes.
OK | |
| |
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE ()
|
|
2.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR - BATTERY AND BODY GROUND) |
Disconnect the A29 blower with fan motor sub-assembly connector.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection | Condition | Specified Condition |
A29-3 (+B) - Body ground | Always | 11 to 14 V |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection | Condition | Specified Condition |
A29-1 (GND) - Body ground | Always | Below 1 Ω |
Text in Illustration*a | Front view of wire harness connector (to Blower with Fan Motor Sub-assembly) |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the E81 air conditioning amplifier assembly connector.
Disconnect the A29 blower with fan motor sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection | Condition | Specified Condition |
E81-23 (BLW) - A29-2 (SI) | Always | Below 1 Ω |
E81-23 (BLW) - Body ground | Always | 10 kΩ or higher |
E81-14 (GND) - Body ground | Always | Below 1 Ω |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |
Remove the air conditioning amplifier assembly with its connectors still connected ().
Using an oscilloscope, check the waveform.
Measurement ConditionItem | Content |
Terminal No. (Symbol) | E81-23 (BLW) - E81-14 (GND) |
Tool Setting | 1 V/DIV., 500 μs/DIV. |
Condition | Ignition switch ON Blower switch LO level |
- OK:
- Waveform is as shown in the illustration.
Text in Illustration*a | Component with harness connected (Air Conditioning Amplifier Assembly) |
- Waveform varies with the blower level.
| REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY ()
|
|
|
5.REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY |
Temporarily replace the blower with fan motor sub-assembly with a new or normally functioning one ().
6.CHECK BLOWER WITH FAN MOTOR SUB-ASSEMBLY |
Operate the blower with fan motor sub-assembly to check that it functions properly.
- OK:
- Blower with fan motor sub-assembly operates normally.
| REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY ()
|
|
|
OK | |
| |
END (BLOWER WITH FAN MOTOR SUB-ASSEMBLY IS FAULTY) |
|