Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - AB60F AUTOMATIC TRANSMISSION / TRANSAXLE
TRANSMISSION WIRE - INSPECTION
1. INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR) |

Measure the resistance according to the value(s) in the table below.
- HINT:
- If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
- Standard Resistance:
Tester Connection ATF Temperature Specified Condition 1 (OT-) - 9 (OT+) 10°C (50°F) 5 to 8 kΩ 1 (OT-) - 9 (OT+) 25°C (77°F) 2.5 to 4.5 kΩ 1 (OT-) - 9 (OT+) 110°C (230°F) 0.22 to 0.28 kΩ 2 (OT2-) - 10 (OT2+) 10°C (50°F) 5 to 8 kΩ 2 (OT2-) - 10 (OT2+) 25°C (77°F) 2.5 to 4.5 kΩ 2 (OT2-) - 10 (OT2+) 110°C (230°F) 0.22 to 0.28 kΩ
If the result is not as specified, replace the transmission wire.