Dtc B1412/12 Ambient Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK ENGINE TYPE
CHECK MULTIPLEX COMMUNICATION SYSTEM
CHECK CAN COMMUNICATION SYSTEM
READ VALUE OF INTELLIGENT TESTER
INSPECT AMBIENT TEMPERATURE SENSOR
CHECK WIRE HARNESS (AMBIENT TEMPERATURE SENSOR - ECM)
READ VALUE OF INTELLIGENT TESTER
INSPECT AMBIENT TEMPERATURE SENSOR
CHECK WIRE HARNESS (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER)
DTC B1412/12 Ambient Temperature Sensor Circuit |
DESCRIPTION
4GR-FSE:
- The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the ECM and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier via the ECM. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The ECM applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes. The ECM sends the signal to the A/C amplifier via CAN and body multiplex communication.
2AD-FHV:
- The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
DTC No.
| DTC Detection Condition
| Trouble Area
|
B1412/12
| Open or short in ambient temperature sensor circuit
| 4GR-FSE: - Ambient temperature sensor
- Harness and connector between ambient temperature sensor and ECM
- ECM
- Multiplex communication circuit
- A/C amplifier
|
2AD-FHV: - Ambient temperature sensor
- Harness or connector between ambient temperature sensor and A/C amplifier
- A/C amplifier
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Check the engine type.
- Result:
Result
| Proceed to
|
4GR-FSE (Gasoline engine)
| A
|
2AD-FHV (Diesel engine)
| B
|
2.CHECK MULTIPLEX COMMUNICATION SYSTEM |
Use the intelligent tester to check if the Multiplex Communication System (MPX) is functioning normally.
- Result:
Result
| Proceed to
|
MPX DTC is not output
| A
|
MPX DTC is output
| B
|
| GO TO MULTIPLEX COMMUNICATION SYSTEM |
|
|
3.CHECK CAN COMMUNICATION SYSTEM |
Use the intelligent tester to check if the CAN Communication System is functioning normally.
- Result:
Result
| Proceed to
|
CAN DTC is not output
| A
|
CAN DTC is output
| B
|
| GO TO CAN COMMUNICATION SYSTEM |
|
|
4.READ VALUE OF INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
Data List / Air Conditioner:Item
| Measurement Item / Display (Range)
| Normal Condition
| Diagnostic Note
|
Ambient Temp Sensor (Ambi Temp Sens)
| Ambient temperature sensor / Min: -23.3°C (-9.94°F), Max: 65.95°C (150.71°F)
| Actual ambient temperature is displayed
| Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F)
|
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
| Proceed to
|
NG
| A
|
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
| B
|
OK (When troubleshooting according to the DTC)
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|
|
| REPLACE AIR CONDITIONING AMPLIFIER |
|
|
5.INSPECT AMBIENT TEMPERATURE SENSOR |
Remove the ambient temperature sensor.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
B5-1 - B5-2
| 10°C (50°F)
| 3.00 to 3.73 kΩ
|
B5-1 - B5-2
| 15°C (59°F)
| 2.45 to 2.88 kΩ
|
B5-1 - B5-2
| 20°C (68°F)
| 1.95 to 2.30 kΩ
|
B5-1 - B5-2
| 25°C (77°F)
| 1.60 to 1.80 kΩ
|
B5-1 - B5-2
| 30°C (86°F)
| 1.28 to 1.47 kΩ
|
B5-1 - B5-2
| 35°C (95°F)
| 1.00 to 1.22 kΩ
|
B5-1 - B5-2
| 40°C (104°F)
| 0.80 to 1.00 kΩ
|
B5-1 - B5-2
| 45°C (113°F)
| 0.65 to 0.85 kΩ
|
B5-1 - B5-2
| 50°C (122°F)
| 0.50 to 0.70 kΩ
|
B5-1 - B5-2
| 55°C (131°F)
| 0.44 to 0.60 kΩ
|
B5-1 - B5-2
| 60°C (140°F)
| 0.36 to 0.50 kΩ
|
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
| REPLACE AMBIENT TEMPERATURE SENSOR |
|
|
6.CHECK WIRE HARNESS (AMBIENT TEMPERATURE SENSOR - ECM) |
Disconnect the ambient temperature sensor connector.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
B5-1 - A5-18 (TAM)
| Always
| Below 1 Ω
|
B5-2 - E5-30 (E3)
| Always
| Below 1 Ω
|
A5-18 (TAM) - Body ground
| Always
| 10 kΩ or higher
|
E5-30 (E3) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
7.READ VALUE OF INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the display on the intelligent tester.
Data List / Air Conditioner:Item
| Measurement Item / Display (Range)
| Normal Condition
| Diagnostic Note
|
Ambient Temp Sensor (Ambi Temp Sens)
| Ambient temperature sensor / Min: -23.3°C (-9.94°F), Max: 65.95°C (150.71°F)
| Actual ambient temperature is displayed
| Open in circuit: -23.3°C (-9.94°F) Short in circuit: 65.95°C (150.71°F)
|
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
| Proceed to
|
NG
| A
|
OK (When troubleshooting according to the PROBLEM SYMPTOMS TABLE)
| B
|
OK (When troubleshooting according to the DTC)
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|
|
| REPLACE AIR CONDITIONING AMPLIFIER |
|
|
8.INSPECT AMBIENT TEMPERATURE SENSOR |
Remove the ambient temperature sensor.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
B5-1 - B5-2
| 10°C (50°F)
| 3.00 to 3.73 kΩ
|
B5-1 - B5-2
| 15°C (59°F)
| 2.45 to 2.88 kΩ
|
B5-1 - B5-2
| 20°C (68°F)
| 1.95 to 2.30 kΩ
|
B5-1 - B5-2
| 25°C (77°F)
| 1.60 to 1.80 kΩ
|
B5-1 - B5-2
| 30°C (86°F)
| 1.28 to 1.47 kΩ
|
B5-1 - B5-2
| 35°C (95°F)
| 1.00 to 1.22 kΩ
|
B5-1 - B5-2
| 40°C (104°F)
| 0.80 to 1.00 kΩ
|
B5-1 - B5-2
| 45°C (113°F)
| 0.65 to 0.85 kΩ
|
B5-1 - B5-2
| 50°C (122°F)
| 0.50 to 0.70 kΩ
|
B5-1 - B5-2
| 55°C (131°F)
| 0.44 to 0.60 kΩ
|
B5-1 - B5-2
| 60°C (140°F)
| 0.36 to 0.50 kΩ
|
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
| REPLACE AMBIENT TEMPERATURE SENSOR |
|
|
9.CHECK WIRE HARNESS (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER) |
Disconnect the ambient temperature sensor connector.
Disconnect the A/C amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
B5-1 - J58-36 (TAM)
| Always
| Below 1 Ω
|
B5-2 - J58-37 (SG)
| Always
| Below 1 Ω
|
J58-36 (TAM) - Body ground
| Always
| 10 kΩ or higher
|
J58-37 (SG) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER |
|