Meter / Gauge System Entire Combination Meter Does Not Operate

Body Electrical. Lexus Gs430, Gs300. Uzs190 Grs190
Meter. Lexus Gs430, Gs300. Uzs190 Grs190

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT COMBINATION METER (POWER SOURCE SYSTEM)

INSPECT COMBINATION METER (AUTOMATIC LIGHT CONTROL SENSOR SYSTEM)

INSPECT AUTOMATIC LIGHT CONTROL SENSOR

METER / GAUGE SYSTEM - Entire Combination Meter does not Operate


WIRING DIAGRAM


Lexus Gs430, Gs300. Uzs190 Grs190.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate


INSPECTION PROCEDURE

1.INSPECT COMBINATION METER (POWER SOURCE SYSTEM)


    Lexus Gs430, Gs300. Uzs190 Grs190.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate
  1. Disconnect the L31 connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Terminal No.
    Condition
    Specified Condition
    L31-20 - Body ground
    Always
    Below 1 Ω
  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Terminal No.
    Condition
    Specified Condition
    L31-1 - Body ground
    Always
    10 to 14 V
    L31-21 - Body ground
    Always
    10 to 14 V
    L31-22 - Body ground
    Always
    10 to 14 V


NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK


2.INSPECT COMBINATION METER (AUTOMATIC LIGHT CONTROL SENSOR SYSTEM)


    Lexus Gs430, Gs300. Uzs190 Grs190.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate
  1. Disconnect the L31 connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Terminal No.
    Condition
    Specified Condition
    L31-36 - Body ground
    Always
    10 kΩ or higher


NG
Go to step 3
OK

REPLACE COMBINATION METER

3.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
  1. Disconnect the W33 automatic light control sensor connector.



    Lexus Gs430, Gs300. Uzs190 Grs190.Meter.Meter / Gauge System.Meter / Gauge System  Entire Combination Meter Does Not Operate
  1. Disconnect the L31 connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance:
    Terminal No.
    Condition
    Specified Condition
    L31-36 - L31-18
    Always
    10 kΩ or higher
    L31-36 - Body ground
    Always
    10 kΩ or higher


NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE AUTOMATIC LIGHT CONTROL SENSOR