Charging System On-Vehicle Inspection

Engine. Lexus Gs430, Gs300. Uzs190 Grs190
3Gr-Fe Charging. Lexus Gs430, Gs300. Uzs190 Grs190

  1. CHECK BATTERY CONDITION

  2. CHECK BATTERY TERMINAL AND FUSE

  3. CHECK V-RIBBED BELT

  4. VISUALLY CHECK GENERATOR WIRING

  5. LISTEN FOR ABNORMAL NOISE FROM GENERATOR

  6. CHECK CHARGE WARNING LIGHT CIRCUIT

  7. CHECK CHARGING CIRCUIT WITHOUT LOAD

  8. CHECK CHARGING CIRCUIT WITH LOAD

Charging System -- On-Vehicle Inspection



1. CHECK BATTERY CONDITION
NOTICE:
If the battery is weak or if the engine is difficult to start, perform the following procedures.
  1. Check the battery for damage and deformation. If severe damage, deformation or leakage is found, replace the battery.

  1. Check the electrolyte quantity of each cell.

    1. For maintenance-free batteries:

      1. If the electrolyte quantity is below the lower line, replace the battery.
      1. If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine.
      1. If the voltage is less than 9.6 V, recharge or replace the battery.
      HINT:
      Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).
    2. For non-maintenance-free batteries:

      1. If the electrolyte quantity is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte's specific gravity.
      Standard specific gravity:
      1.25 to 1.29 at 20°C (68°F)
      If the electrolyte quantity is above the lower line, check the battery voltage when cranking the engine. If the voltage is less than 9.6 V, recharge or replace the battery.
      HINT:
      Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear defogger, etc.).


2. CHECK BATTERY TERMINAL AND FUSE
  1. Check that the battery terminals are not loose or corroded.
    If the terminals are corroded, clean the terminals.

  1. Measure the resistance of the H-fuse and fuses.

    Standard resistance:
    Below 1 Ω
    If the results are not as specified, replace fuses as necessary.


3. CHECK V-RIBBED BELT


Lexus Gs430, Gs300. Uzs190 Grs190.3Gr-Fe Charging.Charging System.Charging System  On-Vehicle Inspection
  1. Check the belt for wear, cracks and other signs of damage.
    If any defect is found, replace the drive belt.

    HINT:
    Replace the drive belt, if the following defects are found:
    1. The belt is worn out and wire is exposed.
    1. The cracks reach the wire in more than one place.
    1. The belt has chunks missing from the ribs.


    Lexus Gs430, Gs300. Uzs190 Grs190.3Gr-Fe Charging.Charging System.Charging System  On-Vehicle Inspection
  1. Check that the belt fits properly in the ribbed grooves.

    HINT:
    With your hand, confirm that the belt has not slipped out of the grooves on the bottom of the pulley.


4. VISUALLY CHECK GENERATOR WIRING
  1. Check that the wiring is in good condition.



5. LISTEN FOR ABNORMAL NOISE FROM GENERATOR
  1. Check that the generator does not emit any abnormal noise while the engine is running.



6. CHECK CHARGE WARNING LIGHT CIRCUIT
  1. Turn the engine switch on (IG). Check that the charge warning light turns on.

  1. Start the engine and check that the light turns off.
    If the light does not operate as specified, troubleshoot the charge warning light circuit.



7. CHECK CHARGING CIRCUIT WITHOUT LOAD


    Lexus Gs430, Gs300. Uzs190 Grs190.3Gr-Fe Charging.Charging System.Charging System  On-Vehicle Inspection
  1. Connect a voltmeter and ammeter to the charging circuit as follows.

    HINT:
    If a battery/generator tester is available, connect the tester to the charging circuit according to the manufacturer's instructions.

    1. Disconnect the wire from terminal B of the generator and connect it to the negative (-) lead of the ammeter.

    2. Connect the ammeter's positive (+) lead to terminal B of the generator.

    3. Connect the voltmeter's positive (+) lead to positive (+) terminal of the battery.

    4. Ground the voltmeter's negative (-) lead.

  1. Check the charging circuit.

    1. Keep the engine speed at 5,000 rpm. Check the reading on the ammeter and voltmeter.

      Standard amperage:
      10 A or less
      Standard voltage:
      13.2 to 14.8 V
      If the result is not as specified, replace the generator.
      HINT:
      If the battery is not fully charged, the ammeter reading will sometimes be more than the standard amperage.


8. CHECK CHARGING CIRCUIT WITH LOAD
  1. With the engine running at 2,000 rpm, turn on the high beam headlights and turn the heater blower switch to the HI position.

  1. Check the reading on the ammeter.

    Standard amperage:
    30 A or more
    If the ammeter reading is less than the standard amperage, replace the generator.
    HINT:
    If the battery is fully charged, the ammeter reading will sometimes be less than the standard amperage.