Instrument Panel Safety Pad -- Reassembly |
- HINT:
- Use the same procedure for RHD and LHD vehicles.
- The procedure listed below is for LHD vehicles.
- A bolt without a torque specification is shown in the standard bolt chart (Click here).
1. INSTALL NO. 2 INSTRUMENT PANEL WIRE (for LHD) |
Attach the clamps to install the No. 2 instrument panel wire to the instrument panel.
2. INSTALL NO. 2 INSTRUMENT PANEL WIRE (for RHD) |
Attach the clamps to install the No. 2 instrument panel wire to the instrument panel.
3. INSTALL ANTENNA CORD SUB-ASSEMBLY (w/o Multi-display) |
for LHD:
Attach the 7 clamps to install the antenna cord.
for RHD:
Attach the 5 clamps to install the antenna cord.
4. INSTALL ANTENNA CORD SUB-ASSEMBLY (w/ Multi-display) |
for LHD:
Attach the 8 clamps to install the antenna cord.
for RHD:
Attach the 6 clamps to install the antenna cord.
5. INSTALL NAVIGATION ANTENNA ASSEMBLY (w/ Multi-display) |
for LHD:
Install the navigation antenna assembly with the 2 screws.
Attach the 2 clamps.
for RHD:
Install the navigation antenna assembly with the 2 screws.
Attach the 2 clamps.
6. INSTALL NO. 2 SIDE DEFROSTER NOZZLE |
Attach the 3 claws to install the No. 2 side defroster nozzle.
![]() |
7. INSTALL NO. 1 SIDE DEFROSTER NOZZLE |
Attach the 2 claws to install the No. 1 side defroster nozzle.
![]() |
8. INSTALL DEFROSTER NOZZLE ASSEMBLY |
Attach the 11 claws to install the defroster nozzle.
![]() |
9. INSTALL FRONT PASSENGER AIRBAG ASSEMBLY |
Attach the 5 hooks (A).
![]() |
Attach the 5 hooks (B) to install the front passenger airbag on the instrument panel.
Install the 2 screws.
![]() |
Connect the 2 connectors and install the instrument panel wire assembly to the front passenger airbag.
- NOTICE:
- When handling the airbag connector, take care not to damage the airbag wire harness.
![]() |
Attach the claw and install the wire.
10. INSTALL REAR NO. 1 AIR DUCT (w/ Rear Air Duct) |
Install the rear No. 1 air duct with the 2 screws.
![]() |
11. INSTALL CENTER HEATER TO REGISTER DUCT |
Install the center heater to register duct with the 3 screws.
![]() |