Dtc B1419/19 Rear Room Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (ROOM TEMP SENSOR [REAR])
INSPECT COOLER THERMISTOR (REAR ROOM TEMPERATURE SENSOR)
CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR [REAR ROOM
TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY)
DTC B1419/19 Rear Room Temperature Sensor Circuit |
DESCRIPTION
- *1: for LHD
- *2: for RHD
The cooler thermistor (rear room temperature sensor LH*1 or RH*2) is installed in the rear quarter trim board LH*1 or RH*2 to detect the rear room temperature and control the heater and air conditioner "auto" mode. The resistance of the rear room temperature sensor LH*1 or RH*2 changes in accordance with the cooler thermistor (rear room temperature sensor LH*1or RH*2) seat. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (rear room temperature sensor LH*1 or RH*2) and reads voltage changes as changes in the resistance of the cooler thermistor (rear room temperature sensor LH* or RH*2)DTC Code
| DTC Detection Condition
| Trouble Area
|
B1419/19
| An open or short in the cooler thermistor (rear room temperature sensor LH*1 or RH*2) circuit.
| - Cooler thermistor (rear room temperature sensor LH)*1
- Cooler thermistor (rear room temperature sensor RH)*2
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (ROOM TEMP SENSOR [REAR]) |
- *1: for LHD
- *2: for RHD
Use the Data List to check if the rear room temperature sensor LH*1 or RH*2 is functioning properly (Click here).
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Room Temp Sensor (Rear)
| Cooler thermistor (rear room temperature sensor for LH*1,RH*2) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F)
| Actual rear room temperature for LH*1 or RH*2 displayed
| Cooler thermistor (rear room temperature sensor for LH*1 or RH*2) system malfunction:
- Open in the circuit: -6.5°C (20.3°F)
- Short in the circuit: 57.25°C (135.05°F)
|
- OK:
- The display is as specified in the normal condition.
ResultResult
| Proceed to
|
OK (When troubleshooting according to the DTC)
| A
|
OK (When troubleshooting according to Problem Symptoms Table)
| B
|
NG
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here) |
|
|
| |
|
A |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|
2.INSPECT COOLER THERMISTOR (REAR ROOM TEMPERATURE SENSOR) |
for LHD:
Remove the cooler thermistor (rear room temperature sensor LH) (Click here).
for RHD
Remove the cooler thermistor (rear room temperature sensor RH) (Click here).
Inspect the cooler thermistor (rear room temperature sensor) (Click here).
ResultResult
| Proceed to
|
OK
| A
|
NG (for LHD)
| B
|
NG (for RHD)
| C
|
| REPLACE COOLER THERMISTOR (REAR ROOM TEMPERATURE SENSOR LH) (Click here) |
|
|
| REPLACE COOLER THERMISTOR (REAR ROOM TEMPERATURE SENSOR RH) (Click here) |
|
|
3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR [REAR ROOM
TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
for LHD:
Disconnect the z55 cooler thermistor (rear room temperature sensor LH) connector.
Disconnect the E35 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
z55-1 - E35-21 (TR)
| Always
| Below 1 Ω
|
z55-2 - E35-33 (SG)
| Always
| Below 1 Ω
|
z55-1 - z55-2
| Always
| 10 kΩ or higher
|
z55-1 or E35-21 (TR) - Body ground
| Always
| 10 kΩ or higher
|
z55-2 or E35-33 (SG) - Body ground
| Always
| 10 kΩ or higher
|
for RHD:
Disconnect the z56 cooler thermistor (rear room temperature sensor RH) connector.
Disconnect the E35 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
z56-1 - E35-22 (TEST)
| Always
| Below 1 Ω
|
z56-2 - E35-33 (SG)
| Always
| Below 1 Ω
|
z55-1 - z55-2
| Always
| 10 kΩ or higher
|
z56-1 or E35-22 (TEST) - Body ground
| Always
| 10 kΩ or higher
|
z56-2 or E35-33 (SG) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|