Dtc B1411/11 Room Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (ROOM TEMPERATURE SENSOR)
INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR [ROOM TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY)
DTC B1411/11 Room Temperature Sensor Circuit |
DESCRIPTION
The front room temperature sensor for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner "auto" mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the front room temperature sensor and reads voltage changes as the resistance of the front room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.DTC Code
| DTC Detection Condition
| Trouble Area
|
B1411/11
| An open or short in the front room temperature sensor circuit.
| - Cooler thermistor (room temperature sensor)
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (ROOM TEMPERATURE SENSOR) |
Use the Data List to check if the cooler thermistor (room temperature sensor) is functioning properly (Click here).
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Room Temperature Sensor
| Cooler thermistor (room temperature sensor) / Min.: -6.5°C (20.3°F), Max.: 57.25°C (135.05°F)
| Actual room temperature for front seat displayed
| Cooler thermistor (room temperature sensor) system malfunction:
- pen in the circuit: -6.5°C (20.3°F)O
- Short in the circuit: 57.25°C (135.05°F)
|
- OK:
- The display is as specified in the normal condition.
ResultResult
| Proceed to
|
OK (When troubleshooting according to the DTC)
| A
|
OK (When troubleshooting according to Problem Symptoms Table)
| B
|
NG
| C
|
| PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here) |
|
|
| |
|
A |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|
2.INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) |
Remove the cooler thermistor (room temperature sensor) (Click here).
Inspect the cooler thermistor (room temperature sensor) (Click here).
| REPLACE COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) (Click here) |
|
|
3.CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR [ROOM TEMPERATURE SENSOR] - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
w/ Rear Heater:
Disconnect the E32 cooler thermistor (room temperature sensor) connector.
Disconnect the E35 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E32-1 - E35-16 (TR)
| Always
| Below 1 Ω
|
E32-2 - E35-1 (SG-1)
| Always
| Below 1 Ω
|
E32-1 - E32-2
| Always
| 10 kΩ or higher
|
E32-1 or E35-16 (TR) - Body ground
| Always
| 10 kΩ or higher
|
E32-2 or E35-1 (SG-1) - Body ground
| Always
| Below 1 Ω
|
w/o Rear Heater:
Disconnect the E32 cooler thermistor (room temperature sensor) connector.
Disconnect the E165 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E32-1 - E165-4 (TR)
| Always
| Below 1 Ω
|
E32-2 - E165-8 (SG-1)
| Always
| Below 1 Ω
|
E32-1 - E32-2
| Always
| 10 kΩ or higher
|
E32-1 or E165-4 (TR) - Body ground
| Always
| 10 kΩ or higher
|
E32-2 or E165-8 (SG-1) - Body ground
| Always
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here) |
|