Power Tilt And Power Telescopic Steering Column System Data List / Active Test

Steering. Land Cruiser. Urj200, 202 Grj200 Vdj200
Steering Column. Land Cruiser. Urj200, 202 Grj200 Vdj200
  1. READ DATA LIST

  1. PERFORM ACTIVE TEST

Power Tilt And Power Telescopic Steering Column System -- Data List / Active Test



READ DATA LIST
HINT:
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
  1. Connect the intelligent tester to the DLC3.

  2. Turn the engine switch on (IG).

  3. Turn the intelligent tester on.

  4. Enter the following menus: Body Electrical / Tilt & Telescopic / Data List.

  5. Check the values by referring to the table below.

    Tilt & Telescopic
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tilt Position
    Current tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Position
    Current telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Return Position
    Memorized tilt return position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Return Position
    Memorized telescopic return position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Memory Pos 1
    Tilt data of memory position 1/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Memory Pos 1
    Telescopic data of memory position 1/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Memory Pos 2
    Tilt data of memory position 2/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Memory Pos 2
    Telescopic data of memory position 2/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Memory Pos 3
    Tilt data of memory position 3/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Memory Pos 3
    Telescopic data of memory position 3/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Up Limit
    Uppermost tilt position/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    Tilt Up Limit Position
    Uppermost tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Down Limit
    Lowermost tilt position/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    Tilt Down Limit Position
    Lowermost tilt position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Short Limit
    Shortest telescopic position/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    Telesco Short Limit Pos
    Shortest telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Telesco Long Limit
    Longest telescopic position/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    Telesco Long Limit Pos
    Longest telescopic position data/min.: 0000 H (0 edges), max.: FFFF H (65535 edges)
    7000 to 9000 H
    (28672 to 36864 edges)
    -
    Tilt Up Switch
    Input state of tilt up by manual switch/ON or OFF
    ON: Tilt up activated by manual switch
    OFF: Tilt up not activated by manual switch
    -
    Tilt Up SW (CAN)
    Input state of tilt up by manual switch/ON or OFF
    ON: Tilt up activated by manual switch
    OFF: Tilt up not activated by manual switch
    -
    Tilt Down Switch
    Input state of tilt down by manual switch/ON or OFF
    ON: Tilt down activated by manual switch
    OFF: Tilt down not activated by manual switch
    -
    Tilt Down SW (CAN)
    Input state of tilt down by manual switch/ON or OFF
    ON: Tilt down activated by manual switch
    OFF: Tilt down not activated by manual switch
    -
    Telesco Short Switch
    Input state of telescopic short by manual switch/ON or OFF
    ON: Telescopic short activated by manual switch
    OFF: Telescopic short not activated by manual switch
    -
    Telesco Short SW (CAN)
    Input state of telescopic short by manual switch/ON or OFF
    ON: Telescopic short activated by manual switch
    OFF: Telescopic short not activated by manual switch
    -
    Telesco Long Switch
    Input state of telescopic long by manual switch/ON or OFF
    ON: Telescopic long activated by manual switch
    OFF: Telescopic long not activated by manual switch
    -
    Telesco Long SW (CAN)
    Input state of telescopic long by manual switch/ON or OFF
    ON: Telescopic long activated by manual switch
    OFF: Telescopic long not activated by manual switch
    -
    T&T Manual SW Data
    Voltage data of manual switch/min.: 0 V, max.: 5 V
    Neutral position: Below 0.2 V
    Tilt up: 1.67 to 2.13 V
    Tilt down: 0.54 to 0.74 V
    Telescopic contract: 1.08 to 1.40 V
    Telescopic extend: 2.22 to 2.77 V
    -
    S/B Mem 1
    Tilt and telescopic memory position 1/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    S/B Mem 2
    Tilt and telescopic memory position 2/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    S/B Mem 3
    Tilt and telescopic memory position 3/Not Mem or Mem
    Not Mem: Position not memorized
    Mem: Position memorized
    -
    T&T Autoaway Function
    Auto away/return function/ON or OFF
    ON: Auto away/return function allowed
    OFF: Auto away/return function prohibited
    -
    Power Source Voltage
    Voltage data of power supply/min.: 0 V, max.: 20 V
    Actual power supply voltage
    11 to 14 V
    -
    Freeze Speed Info
    Vehicle speed data/min.: 0 km/h (0 mph), max.: 255 km/h (158 mph)
    Actual vehicle speed
    -
    IG Switch (CAN)
    Communication state of engine switch/ON or OFF
    ON: Communication normal
    OFF: Communication interrupted
    -
    IG Switch
    Input state of engine switch/ON or OFF
    ON: Input signal normal
    OFF: Input signal interrupted
    -
    Key Code Confirm (CAN)
    Communication state of key code confirmation signal/ON or OFF
    ON: Communication normal
    OFF: Communication interrupted
    -
    Receive from Meter
    Communication state of combination meter signal/OK or Interruption
    OK: Communication normal
    Interruption: Communication interrupted
    -
    Receive from Seat ECU
    Communication state of position control ECU signal/OK or Interruption
    OK: Communication normal
    Interruption: Communication interrupted
    -
    Receive from Combi
    Communication state of combination switch ECU signal/OK or Interruption
    OK: Communication normal
    Interruption: Communication interrupted
    -
    J/B
    Communication state of main body ECU signal/OK or Interruption
    OK: Communication normal
    Interruption: Communication interrupted
    -
    B/B
    Communication state of optional after parts ECU signal/OK or Interruption
    OK: Communication normal
    Interruption: Communication interrupted
    -
    Driver Seat Buckle SW
    Driver side buckle switch signal / Set, Unset or Unknown
    -
    -
    The Number of DTCs
    Number of diagnostic trouble codes/min.: 0, max.: 255
    Actual number of diagnostic trouble codes
    -


PERFORM ACTIVE TEST
HINT:
Using the intelligent tester to perform Active Test allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Test early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Test.
  1. Connect the intelligent tester to the DLC3.

  2. Turn the engine switch on (IG).

  3. Turn the intelligent tester on.

  4. Enter the following menus: Body Electrical / Tilt & Telescopic / Active Test.

  5. Check the values by referring to the table below.

    Tilt & Telescopic
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Tilt Operation
    Tilt operation
    Up/Down
    -
    Telesco Operation
    Telescopic operation
    Long/Short
    -