Brake. Land Cruiser. Urj200, 202 Grj200 Vdj200
Brake Control Dynamic Control Systems. Land Cruiser. Urj200, 202 Grj200 Vdj200
Yaw Rate And Deceleration Sensor (W/ Vsc) -- Installation |
1. INSTALL YAW RATE SENSOR |
Connect the sensor connector, and then attach the clamp to the hole of the sensor bracket.
- NOTICE:
- Securely connect the connector.
Install the yaw rate sensor with the 2 bolts.
- Torque:
- 15 N*m{148 kgf*cm, 11 ft.*lbf}
- NOTICE:
- Make sure that the sensor is oriented correctly.
- If the sensor is dropped, replace it.
- When installing the sensor, make sure to avoid impacts to the sensor.
2. INSTALL COOLING BOX ASSEMBLY (w/ Cool Box) |
3. INSTALL REAR CONSOLE BOX SUB-ASSEMBLY (w/o Cool Box) |
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
5. PERFORM YAW RATE SENSOR ZERO POINT CALIBRATION |
Perform the yaw rate sensor zero point calibration (Click here).
6. CHECK YAW RATE SENSOR SIGNAL |
Check the yaw rate sensor signal (Click here).