Ecd System (W/ Dpf) Ecm Power Source Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT INTEGRATION RELAY (POWER SOURCE)
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - BODY GROUND)
INSPECT INTEGRATION RELAY (EFI MAIN NO. 1 AND IG2 MAIN)
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)
CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
INSPECT ECM (IGSW VOLTAGE)
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)
CHECK ENTRY AND START SYSTEM (SMART KEY ECU ASSEMBLY - INTEGRATION RELAY)
ECD SYSTEM (w/ DPF) - ECM Power Source Circuit |
DESCRIPTION
When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to terminal +B of the ECM.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
1.INSPECT INTEGRATION RELAY (POWER SOURCE) |
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHDTester Connection
| Condition
| Specified Condition
|
1Y-1 - Body ground
| Always
| 11 to 14 V
|
for RHDTester Connection
| Condition
| Specified Condition
|
1X-1 - Body ground
| Always
| 11 to 14 V
|
*a
| Front view of wire harness connector (Integration relay)
|
*b
| for LHD
|
*c
| for RHD
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
2.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - BODY GROUND) |
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1S-4 - Body ground
| Always
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT INTEGRATION RELAY (EFI MAIN NO. 1 AND IG2 MAIN) |
Inspect the integration relay (Click here).
| REPLACE INTEGRATION RELAY |
|
|
4.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM) |
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Condition
| Specified Condition
|
A38-44 (MREL) - 1S-8
| Always
| Below 1 Ω
|
A38-2 (+B) - 1S-11
| Always
| Below 1 Ω
|
A38-1 (+B2) - 1S-11
| Always
| Below 1 Ω
|
A38-44 (MREL) or 1S-8 - Body ground
| Always
| 10 kΩ or higher
|
A38-2 (+B) or 1S-11 - Body ground
| Always
| 10 kΩ or higher
|
A38-1 (+B2) or 1S-11 - Body ground
| Always
| 10 kΩ or higher
|
for RHDTester Connection
| Condition
| Specified Condition
|
A52-44 (MREL) - 1S-8
| Always
| Below 1 Ω
|
A52-2 (+B) - 1S-11
| Always
| Below 1 Ω
|
A52-1 (+B2) - 1S-11
| Always
| Below 1 Ω
|
A52-44 (MREL) or 1S-8 - Body ground
| Always
| 10 kΩ or higher
|
A52-2 (+B) or 1S-11 - Body ground
| Always
| 10 kΩ or higher
|
A52-1 (+B2) or 1S-11 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
5.CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Condition
| Specified Condition
|
C45-81 - Body ground
| Always
| Below 1 Ω
|
for RHDTester Connection
| Condition
| Specified Condition
|
C46-81 - Body ground
| Always
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
6.INSPECT ECM (IGSW VOLTAGE) |
Disconnect the ECM connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LHDTester Connection
| Switch Condition
| Specified Condition
|
A38-28 (IGSW) - C45-81 (E1)
| Ignition switch ON
| 11 to 14 V
|
for RHDTester Connection
| Switch Condition
| Specified Condition
|
A52-28 (IGSW) - C46-81 (E1)
| Ignition switch ON
| 11 to 14 V
|
7.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM) |
Disconnect the ECM connector.
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection
| Condition
| Specified Condition
|
A38-28 (IGSW) - 1P-7
| Always
| Below 1 Ω
|
A38-28 (IGSW) or 1P-7 - Body ground
| Always
| 10 kΩ or higher
|
for RHDTester Connection
| Condition
| Specified Condition
|
A52-28 (IGSW) - 1P-7
| Always
| Below 1 Ω
|
A52-28 (IGSW) or 1P-7 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
8.CHECK ENTRY AND START SYSTEM (SMART KEY ECU ASSEMBLY - INTEGRATION RELAY) |
Disconnect the smart key ECU assembly connector.
Disconnect the integration relay connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E128-3 (IG1D) - 1R-2
| Always
| Below 1 Ω
|
E128-3 (IG1D) or 1R-2 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|