Heated Oxygen Sensor Inspection
INSPECT HEATED OXYGEN SENSOR
Heated Oxygen Sensor -- Inspection |
1. INSPECT HEATED OXYGEN SENSOR |
Measure the heater resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 (HT1B) - 2 (+B) (for Bank 1)
| 20°C (68°F)
| 11 to 16 Ω
|
1 (HT2B) - 2 (+B) (for Bank 2)
|
Text in Illustration*A
| for Bank 1
|
*B
| for Bank 2
|
*a
| Component without harness connected (Heated Oxygen Sensor)
|
If the result is not as specified, replace the sensor.