Система Ecd Starter Signal Circuit


DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

When using intelligent tester:

READ VALUE USING INTELLIGENT TESTER (STA SIGNAL)

CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM)

When not using intelligent tester:

CHECK ECM (STA VOLTAGE)

CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM)

СИСТЕМА ECD - Starter Signal Circuit


DESCRIPTION

When the engine is cranked, the intake air flow becomes slow so fuel vaporization is poor. A rich mixture is therefore necessary in order to achieve good startability. While the engine is being cranked, the battery voltage is applied to terminal STA of the ECM. The starter signal is mainly used to increase the fuel injection volume for starting and after-start injection control.

WIRING DIAGRAM


.Система Управления Двигателем 5L-E.Система Ecd.Система Ecd  Starter Signal Circuit


INSPECTION PROCEDURE


When using intelligent tester:

1.READ VALUE USING INTELLIGENT TESTER (STA SIGNAL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON and turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.

  1. Read the STA signal on the intelligent tester while the starter operates.

    OK:
    Ignition Switch Position
    STA Signal
    LOCK, ACC, ON
    OFF
    START
    ON


NG
Перейдите к шагу 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Нажмите здесь)

2.CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM)
  1. Disconnect the clutch start switch connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD
    Tester Connection
    Condition
    Specified Condition
    A41-1 - G61-11 (STA)
    Always
    Below 1 Ω
    for RHD
    Tester Connection
    Condition
    Specified Condition
    r2-1 - G61-11 (STA)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    for LHD
    Tester Connection
    Condition
    Specified Condition
    A41-1 or G61-11 (STA) - Body ground
    Always
    10 kΩ higher
    for RHD
    Tester Connection
    Condition
    Specified Condition
    r2-1 or G61-11 (STA) - Body ground
    Always
    10 kΩ higher
  1. Reconnect the clutch start switch connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Нажмите здесь)


When not using intelligent tester:

1.CHECK ECM (STA VOLTAGE)
.Система Управления Двигателем 5L-E.Система Ecd.Система Ecd  Starter Signal Circuit
  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G61-11 (STA) - C101-14 (E1)
    Cranking
    6 V or higher
    Text in Illustration
    *a
    Component with harness connected
    (ECM)


NG
Перейдите к шагу 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Нажмите здесь)

2.CHECK HARNESS AND CONNECTOR (CLUTCH START SWITCH - ECM)
  1. Disconnect the clutch start switch connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD
    Tester Connection
    Condition
    Specified Condition
    A41-1 - G61-11 (STA)
    Always
    Below 1 Ω
    for RHD
    Tester Connection
    Condition
    Specified Condition
    r2-1 - G61-11 (STA)
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    for LHD
    Tester Connection
    Condition
    Specified Condition
    A41-1 or G61-11 (STA) - Body ground
    Always
    10 kΩ higher
    for RHD
    Tester Connection
    Condition
    Specified Condition
    r2-1 or G61-11 (STA) - Body ground
    Always
    10 kΩ higher
  1. Reconnect the clutch start switch connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Нажмите здесь)