Power Source Network. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Kd-Ftv Battery Charging. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Generator (For Bosch Made) -- Removal |
1. PRECAUTION |
- NOTICE:
- After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (HILUX_TGN26 RM000004QR1006X.html).
2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR3009X.html).
3. REMOVE AIR CLEANER ASSEMBLY |
Disconnect the mass air flow meter connector.
Loosen the hose clamp.
Remove the 2 bolts and air cleaner.
4. REMOVE FAN AND GENERATOR V BELT |
Rotate the tensioner pulley clockwise to loosen the belt and reduce the tension. Then remove the V belt.
Text in Illustration *A w/ Air Conditioning System *B w/o Air Conditioning System *1 Cooler Compressor *2 Fan Pulley *3 Generator *4 Tensioner *5 Crankshaft Pulley
![]() |
5. REMOVE GENERATOR ASSEMBLY |
![]() |
Remove the nut and generator wire.
Disconnect the generator connector.
Remove the 2 bolts and generator.