Thermostat Inspection

Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
1Gr-Fe Cooling. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

Thermostat -- Inspection



1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.1Gr-Fe Cooling.Cooling System.Thermostat  Inspection
HINT:
The valve opening temperature is inscribed on the thermostat.
  1. Immerse the thermostat in the water, then heat the water gradually.

  1. Check the valve opening temperature of the thermostat.

    Standard valve opening temperature:
    80 to 84°C (176 to 183°F)
    If the valve opening temperature is not as specified, replace the water inlet sub-assembly with thermostat.


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.1Gr-Fe Cooling.Cooling System.Thermostat  Inspection
  1. Check the valve lift.

    Standard valve lift:
    8.0 mm (0.315 in.) or more at 95°C (203°F)
    Text in Illustration
    *1
    Valve Lift
    If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.
  1. Check that the valve is fully closed when the thermostat is at low temperature (below 40°C (104°F)).
    If not fully closed, replace the water inlet sub-assembly with thermostat.