Vacuum Switching Valve (W/ Glow Plug Controller) On-Vehicle Inspection

Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
1Kd-Ftv Emission Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSPECT VACUUM SWITCHING VALVE (for EGR Bypass Valve)

Vacuum Switching Valve (W/ Glow Plug Controller) -- On-Vehicle Inspection



1. INSPECT VACUUM SWITCHING VALVE (for EGR Bypass Valve)
  1. Inspect the vacuum switching valve.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      37 to 44 Ω
      1 - Body ground
      2 - Body ground
      20°C (68°F)
      10 kΩ or higher
      If the result is not as specified, replace the vacuum switching valve.


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.1Kd-Ftv Emission Control.Emission Control System.Vacuum Switching Valve (W/ Glow Plug Controller)  On-Vehicle Inspection
  1. Check operation of the vacuum switching valve.

    1. When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.

      Text in Illustration
      *1
      Port E
      *2
      Port F
      *3
      Filter
      *a
      Air
      *b
      Vacuum


    2. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.1Kd-Ftv Emission Control.Emission Control System.Vacuum Switching Valve (W/ Glow Plug Controller)  On-Vehicle Inspection
    3. Apply battery voltage across terminals 1 and 2.

      Text in Illustration
      *1
      Port E
      *2
      Port F
      *a
      Air
    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the vacuum switching valve.