Sfi System Mil Circuit

Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Tr-Fbe Engine Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK THAT MIL IS ILLUMINATED

CHECK WHETHER MIL TURNS OFF

CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)

CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)

CHECK THAT ENGINE STARTS

CHECK COMBINATION METER ASSEMBLY

CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)

SFI SYSTEM - MIL Circuit


DESCRIPTION

The MIL (Malfunction Indicator Lamp) is used to indicate the detection of vehicle malfunctions by the ECM. When the ignition switch is turned to ON, power is supplied to the MIL circuit and the ECM provides the circuit ground which illuminates the MIL.
The MIL operation can be checked visually; when the ignition switch is first turned to ON, the MIL turns on and then off. If the MIL remains illuminated or is not illuminated, conduct the following troubleshooting procedure using the intelligent tester.

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fbe Engine Control.Sfi System.Sfi System  Mil Circuit


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK THAT MIL IS ILLUMINATED
  1. Turn the ignition switch to ON.

  1. Check the illumination condition of the MIL.

    Result
    Condition
    Proceed to
    MIL remains illuminated (Even after ignition switch turned to ON and several seconds have passed, MIL still remains illuminated)
    A
    MIL remains off (Does not illuminate at all)
    B
    MIL illuminates for several seconds, but turns off after engine is started
    C


B
Go to step 5

C
SYSTEM OK
A


2.CHECK WHETHER MIL TURNS OFF
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Check if any DTCs are output. Note down any DTCs.

  1. Clear the DTCs (HILUX_TGN26 RM000000PDK12LX.html).

  1. Check if the MIL goes off.

    OK:
    MIL goes off.


NG
Go to step 3
OK

REPAIR CIRCUITS INDICATED BY OUTPUT DTCS (HILUX_TGN26 RM000000PDF0H4X.html)

3.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT IN WIRE HARNESS)
  1. Disconnect the ECM connector.

  1. Turn the ignition switch to ON.

  1. Check that the MIL is not illuminated.

    OK:
    MIL is not illuminated.
  1. Reconnect the ECM connector.



NG
Go to step 4
OK

REPLACE ECM (HILUX_TGN26 RM000000VW2024X.html)

4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)
  1. Disconnect the combination meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    G19-39 (CHK) or G145-13 (W) - Body ground
    Always
    10 kΩ or higher
  1. Reconnect the combination meter connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER - ECM)
OK

REPLACE COMBINATION METER ASSEMBLY

5.CHECK THAT ENGINE STARTS
  1. Turn the ignition switch to ON.

  1. Check that the engine starts.

    Result
    Result
    Proceed to
    Engine starts
    A
    Engine does not start*
    B
    HINT:
    *: The intelligent tester cannot communicate with the ECM.


B
GO TO VC OUTPUT CIRCUIT (HILUX_TGN26 RM000001D6V0ONX.html)
A


6.CHECK COMBINATION METER ASSEMBLY


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fbe Engine Control.Sfi System.Sfi System  Mil Circuit
  1. Disconnect the ECM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    G145-13 (W) - Body ground
    Ignition switch ON
    11 to 14 V
    Text in Illustration
    *a
    Component with harness connected
    (ECM)


NG
Go to step 7
OK

REPLACE ECM (HILUX_TGN26 RM000000VW2024X.html)

7.CHECK HARNESS AND CONNECTOR (COMBINATION METER - ECM)
  1. Disconnect the combination meter connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G19-39 (CHK) - G145-13 (W)
    Always
    Below 1 Ω
  1. Reconnect the ECM connector.

  1. Reconnect the combination meter connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (COMBINATION METER - ECM)
OK

REPLACE COMBINATION METER ASSEMBLY