Dtc B1413 Evaporator Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING TECHSTREAM
CHECK FOR DTC
INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)
CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
DTC B1413 Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.DTC No.
| DTC Detection Condition
| Trouble Area
|
B1413
| An open or short in the No. 1 cooler thermistor (evaporator temperature sensor) circuit.
| - No. 1 cooler thermistor (evaporator temperature sensor)
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
According to the display on the Techstream, read the Data List.
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Evaporator Fin Thermistor
| Evaporator temperature sensor/ Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F)
| Actual evaporator temperature displayed
| Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F).
|
- OK:
- The display is as specified in the normal condition column.
ResultResult
| Proceed to
|
OK (When troubleshooting according to the DTC)
| A
|
OK (When troubleshooting according to Problem Symptoms Table)
| B
|
NG
| C
|
Clear the DTCs (YARIS_NCP93 RM000001GUF06ZX.html).
Check for DTCs (YARIS_NCP93 RM000001GUF06ZX.html).
- OK:
- DTC B1413 is not output
3.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) |
Inspect the No. 1 cooler thermistor (evaporator temperature sensor) (YARIS_NCP93 RM000000VTW035X.html).
4.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY) |
Disconnect the D123 No. 1 cooler thermistor (evaporator temperature sensor) connector.
Disconnect the D130 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
D123-2 - D130-4 (TE)
| Always
| Below 1 Ω
|
D123-1 - D130-15 (SG-1)
| Always
| Below 1 Ω
|
D123-2 - Body ground
| Always
| 10 kΩ or higher
|
D123-1 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|