Lighting System (For Hatchback) Ig Signal Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING TECHSTREAM
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BATTERY AND BODY GROUND)
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - IGNITION SWITCH)
CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
REPLACE MAIN BODY ECU
READ VALUE USING TECHSTREAM
LIGHTING SYSTEM (for Hatchback) - IG Signal Circuit |
DESCRIPTION
This circuit detects the ignition switch ON or off condition, and sends it to the main body ECU.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the Techstream, read the Data List.
Main BodyTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
IG SW
| Ignition switch ON signal / OFF or ON
| OFF: Ignition switch ACC or off ON: Ignition switch ON
| -
|
- OK:
- Normal conditions listed above are displayed.
2.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BATTERY AND BODY GROUND) |
Disconnect the 3E and 3B instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
3E-1 - Body ground
| Always
| 11 to 14 V
|
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3B-8 - Body ground
| Always
| Below 1 Ω
|
Text in Illustration*a
| Front view of wire harness connector (to Instrument Panel Junction Block Assembly)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - IGNITION SWITCH) |
Reconnect the instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
3A-29 - Body ground
| Ignition switch ON
| 11 to 14 V
|
Text in Illustration*a
| Component with harness connected (Instrument Panel Junction Block Assembly)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
4.CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3A-40 - 3A-54
| Always
| Below 1 Ω
|
3A-40 - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
Replace the main body ECU (YARIS_NCP93 RM000003TOE00CX.html).
6.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Data List.
According to the display on the Techstream, read the Data List.
Main BodyTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
IG SW
| Ignition switch ON signal / OFF or ON
| OFF: Ignition switch ACC or off ON: Ignition switch ON
| -
|
- OK:
- Normal conditions listed above are displayed.
| REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
|
|
OK |
|
|
|
END (MAIN BODY ECU WAS DEFECTIVE) |
|