Drivetrain. Yaris. Ncp93, 131
U340E Automatic Transmission Transaxle. Yaris. Ncp93, 131
Automatic Transaxle System (For Sedan) -- Data List / Active Test |
DATA LIST |
- HINT:
- Using the Techstream to read the Data List allows the values or of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / All Data.
In accordance with the display on the Techstream, read the Data List.
Engine and ECT Tester Display Measurement Item/Range Normal Condition Diagnostic Note Neutral Position SW Signal PNP switch Status/
ON or OFF- ON: Shift lever in P or N
- OFF: Shift lever not in P and N
When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect. - HINT:
- When failure still occurs even after adjusting these parts, (YARIS_NCP93 RM000000W840PUX.html)
Stop Light Switch Stop light switch status/
ON or OFF- ON: Brake pedal is depressed
- OFF: Brake pedal is released
- SPD (NT) Input turbine speed/
display: 50 rpm
min.: 0 rpm
max.: 12750 rpm- Lock-up ON (After warming up engine):
Input turbine speed (NT) equal to engine speed - Lock-up OFF (Idling in P or N position):
Input turbine speed (NT) nearly equal to engine speed - Vehicle stopped in R position: 0 rpm
- Shift SW Status (P Range) PNP switch Status/
ON or OFF- ON: Shift lever in P
- OFF: Shift lever not in P
When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect. - HINT:
- When failure still occurs even after adjusting these parts, (YARIS_NCP93 RM000000W840PUX.html)
Shift SW Status (R Range) PNP switch Status/
ON or OFF- ON: Shift lever in R
- OFF: Shift lever not in R
Shift SW Status (2 Range) PNP switch Status/
ON or OFF- ON: Shift lever in 2
- OFF: Shift lever not in 2
Shift SW Status (L Range) PNP switch Status/
ON or OFF- ON: Shift lever in L
- OFF: Shift lever not in L
Shift SW Status (N Range) PNP switch Status/
ON or OFF- ON: Shift lever in N
- OFF: Shift lever not in N
Shift SW Status (D Range) PNP switch Status/
ON or OFF- ON: Shift lever in D
- OFF: Shift lever not in D
Shift SW Status (3 Range) PNP switch Status/
ON or OFF- ON: Shift lever in 3
- OFF: Shift lever not in 3
A/T Oil Temperature 1 ATF temperature Sensor Value/
min.: -40°C (-40°F)
max.: 215°C (419°F)- After Stall Test: Approximately 80°C (176°F)
- Equal to ambient temperature while engine is cold
If the value is "-40°C (-40°F)" or "150°C (302°F) or more ", ATF temperature sensor circuit is opened or shorted. Lock Up Lock Up status/
ON or OFF- ON: Lock up operating
- OFF: Lock up not operating
- ST Solenoid Status Shift Solenoid ST Status/
ON or OFFUp-shifting and down-shifting between 3rd and 4th gears while driving: OFF → ON → OFF - Shift Status Actual Gear Position/
1st, 2nd, 3rd or 4thShift lever position is: - L: 1st
- 2: 1st or 2nd
- 3: 1st, 2nd or 3rd
- D: 1st, 2nd, 3rd or 4th
- SLT Solenoid Status Shift Solenoid SLT Status/
ON or OFF- ON: Accelerator pedal is released
- OFF: Accelerator pedal is depressed
- SLU Solenoid Status Shift Solenoid SLU Status/
ON or OFF- ON: Lock Up
- OFF: Except Lock Up
- AT Fluid ATF condition ATF condition - ON: NG
- OFF: OK
Replace ATF when ATF condition is ON. Engine and ECT (for Mexico model) Tester Display Measurement Item/Range Normal Condition Diagnostic Note SPD (NT) Input Turbine Speed/
display: 50 rpm
min.: 0 rpm
max.: 12750 rpm- HINT:
- Lock-Up ON (After warming up engine):
Input turbine speed (NT) equal to engine speed - Lock-Up OFF (Idling in P or N position):
Input turbine speed (NT) nearly equal to engine speed - Vehicle stopped in D position: 0 rpm
- Neutral Position SW Signal PNP SW Status/
ON or OFF- ON: Brake pedal is depressed
- OFF: Brake pedal is released
When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect. - HINT:
- When failure still occurs even after adjusting these parts, (YARIS_NCP93 RM000000W840PUX.html).
Stop Light Switch Stop Light SW Status/
ON or OFF- Brake pedal is depressed: ON
- Brake pedal is released: OFF
- Shift Status ECM Gearshift Command/
1st, 2nd, 3rd or 4thShift lever position; - L: 1st
- 2: 1st or 2nd
- 3: 1st, 2nd or 3rd
- D: 1st, 2nd, 3rd or 4th
- Shift SW Status (R Range) PNP SW Status/
ON or OFF- ON: Shift lever in R
- OFF: Shift lever not in R
When shift lever position displayed on Techstream differs from actual position, adjustment of PNP switch or shift cable may be incorrect. - HINT:
- When failure still occurs even after adjusting these parts, (YARIS_NCP93 RM000000W840PUX.html).
Shift SW Status (P Range) PNP SW Status/
ON or OFF- ON: Shift lever in P
- OFF: Shift lever not in P
Shift SW Status (N Range) PNP SW Status/
ON or OFF- ON: Shift lever in N
- OFF: Shift lever not in N
Shift SW Status (D Range) PNP SW Status/
ON or OFF- ON: Shift lever in D or 3
- OFF: Shift lever not in D and 3
Shift SW Status (3 Range) PNP SW Status/
ON or OFF- ON: Shift lever in 3
- OFF: Shift lever not in 3
Shift SW Status (2 Range) PNP SW Status/
ON or OFF- ON: Shift lever in 2
- OFF: Shift lever not in 2
Shift SW Status (L Range) PNP SW Status/
ON or OFF- ON: Shift lever in L
- OFF: Shift lever not in L
A/T Oil Temperature 1 ATF (Automatic Transmission Fluid) Temperature Sensor Value/
min.: -40°C (-40°F)
max.: 215°C (419°F)- After Stall Test: Approximately 80°C (176°F)
- Equal to ambient temperature when cold soak
If value is "-40°C (-40°F)" or "150°C (302°F) or more", ATF temperature sensor circuit is open or short. AT Fluid ATF Condition ATF Condition;
NG: ON
OK: OFFReplace ATF when ATF condition is ON. Lock Up Lock Up Status/
ON or OFF- ON: Lock Up
- OFF: Except Lock Up
- Lock Up Solenoid Status Lock Up Solenoid Status/
ON or OFF- ON: Lock up solenoid ON
- OFF: Lock up solenoid OFF
- ST Solenoid Status Shift Solenoid ST Status/
ON or OFFUp-shifting and down-shifting between 3rd and 4th gears while driving:
OFF → ON → OFF- SLU Solenoid Status Shift Solenoid SLU Status/
ON or OFF- ON: Lock Up
- OFF: Except Lock Up
- SLT Solenoid Status Shift Solenoid SLT Status/
ON or OFF- ON: Accelerator pedal is released
- OFF: Accelerator pedal is depressed
- - ON: Shift lever in P or N
ACTIVE TEST |
- HINT:
- Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
- It is possible to display the Data List during the Active Test.
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Select the following items: Powertrain / Engine and ECT / Active Test.
In accordance with the display on the Techstream, perform the Active Test.
*: Activate the Solenoid (SLT) in the Active Test is performed to check the line pressure changes by connecting SST to the automatic transaxle, which is used in the Hydraulic Test (YARIS_NCP93 RM000000W7B0IJX.html) as well.Engine and ECT Tester Display Test Part Control Range Diagnostic Note Activate the Solenoid (SLU) [Test Details]
Operate shift solenoid SLUON/OFF [Vehicle Condition] - Vehicle Stopped
- Shift lever in P or N
Activate the Solenoid (SLT)* [Test Details]
Operate shift solenoid SLT and raise the line pressure.ON/OFF [Vehicle Condition] - Vehicle Stopped
- Engine idling
- HINT:
- OFF: Line pressure up (When the active test of "Activate the Solenoid (SLT)" is performed, ECM commands SLT solenoid to turn off.)
- ON: No action (normal operation)
Activate the Solenoid (S1) [Test Details]
Operate shift solenoid S1ON/OFF [Vehicle Condition] - Engine Stopped
- Shift lever in P or N
Activate the Solenoid (S2) [Test Details]
Operate shift solenoid S2ON/OFF [Vehicle Condition] - Engine Stopped
- Shift lever in P or N
Activate the Lock Up [Test Details]
Control shift solenoid SLU to set automatic transaxle to lock-up condition.ON/OFF Possible to check SLU operation.
[Vehicle Condition]
Vehicle Speed: 60 km/h (36 mph) or more, and 4th gearControl the Shift Position [Test Details]
Operate shift solenoid valve and set each shift position manually.- Press →button: Shift up
- Press ←button: Shift down
Possible to check operation of shift solenoid valves.
[Vehicle Condition]
Vehicle Speed: Less than 50 km/h (30 mph)Activate the Solenoid (ST) [Test Details]
Operate shift solenoid STON/OFF [Vehicle Condition] - Vehicle Stopped
- Engine idling
- HINT:
- The pressure values in Active Test and Hydraulic Test are different from each other.
- Vehicle Stopped