Meter / Gauge System Fail-Safe Chart
Meter. Camry. Acv40 Gsv40
Meter / Gauge System -- Fail-Safe Chart |
ENGINE COOLANT TEMPERATURE GAUGE:Condition
| Response
| Recovery
|
Engine coolant temperature data is interrupted for 3.1 seconds.
| The gauge needle indicates between / and C.
| Engine coolant temperature data is received.
|
SHIFT INDICATOR (*):Condition
| Response
| Recovery
|
Shift position data is interrupted for 3.1 seconds.
| All indicator light go off.
| Normal data is received.
|
Gear position data is interrupted for 3 seconds.
| The gear position indicator light goes off.
| Normal data is received.
|
ABS & BRAKE:Condition
| Response
| Recovery
|
ABS & brake data is interrupted for 1 second.
| The warning light comes on.
| Normal data is received.
|
DOOR:Condition
| Response
| Recovery
|
Each door condition data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
DRIVER SIDE SEAT BELT:Condition
| Response
| Recovery
|
Driver side front seat inner belt assembly data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
TAIL:Condition
| Response
| Recovery
|
Regular data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
BEAM:Condition
| Response
| Recovery
|
Regular data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
AIRBAG:Condition
| Response
| Recovery
|
Airbag data is interrupted for 10 seconds.
| The warning light comes on.
| Normal data is received.
|
Turn the ignition switch to the ON position, then the combination meter (meter CPU) can't detect the voltage of 9 V or more for 60 seconds.
|
FRONT PASSENGER SIDE SEAT BELT:Condition
| Response
| Recovery
|
Regular data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
CRUISE:Condition
| Response
| Recovery
|
Regular data is interrupted for 10 seconds.
| The data received most recently remains indicated.
| Normal data is received.
|
CHARGE:Condition
| Response
| Recovery
|
Regular data is interrupted.
| The warning light goes off.
| Normal data is received.
|
MULTI-INFORMATION DISPLAY:Condition
| Response
| Recovery
|
Cruise information data is interrupted for 60 seconds.
| The display becomes blank (only measurement units are displayed).
| Normal data is received.
|
*: for Automatic Transaxle