Entry Lock And Unlock Switch Inspection
INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY LH
INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY RH
Entry Lock And Unlock Switch -- Inspection |
1. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY LH |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection (Symbols)
| Condition
| Specified Condition
|
1 (TRG-) - 3 (TRG+)
| Lock switch not pushed
| 10 kΩ or higher
|
1 (TRG-) - 3 (TRG+)
| Lock switch pushed
| Below 1 Ω
|
If the result is not specified, replace the front door outside handle assembly LH.
2. INSPECT FRONT DOOR OUTSIDE HANDLE ASSEMBLY RH |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection (Symbols)
| Condition
| Specified Condition
|
1 (TRG-) - 3 (TRG+)
| Lock switch not pushed
| 10 kΩ or higher
|
1 (TRG-) - 3 (TRG+)
| Lock switch pushed
| Below 1 Ω
|
If the result is not specified, replace the front door outside handle assembly RH.