Dtc P2716 Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)

Transmission. Camry. Acv40 Gsv40
U660E Automatic Transaxle. Camry. Acv40 Gsv40

DESCRIPTION

MONITOR DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT TRANSMISSION WIRE (SLT)

INSPECT SHIFT SOLENOID VALVE SLT

DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)


DESCRIPTION

Refer to DTC P2714 (Link).

DTC No.
DTC Detection Condition
Trouble Area
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. TCM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM


Camry. Acv40 Gsv40.U660E Automatic Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SLT)


    Camry. Acv40 Gsv40.U660E Automatic Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
  1. Remove the TCM from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    7 (SLT-) - 12 (SLT+)
    5.0 to 5.6 Ω
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Check for short:
    Tester Connection
    Specified Condition
    7 (SLT-) - Body ground
    10 kΩ or higher
    12 (SLT+) - Body ground
    10 kΩ or higher


OK
REPLACE TCM
NG


2.INSPECT SHIFT SOLENOID VALVE SLT


    Camry. Acv40 Gsv40.U660E Automatic Transaxle.Automatic Transaxle System.
Dtc
  P2716  Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    1 - 2
    5.0 to 5.6 Ω
  1. Connect a positive (+) lead through a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.


NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPLACE TRANSMISSION WIRE