Lexus IS250 IS220d GSE20 ALE20 4GR-FSE CHARGING
BATTERY CURRENT SENSOR - ON-VEHICLE INSPECTION
1. INSPECT BATTERY CURRENT SENSOR |
Resistance inspection

Using an ohmmeter, measure the resistance between terminals.
- Resistance:
Terminals: Positive (+) tester probe - Negative (-) tester probe Resistance 3 (VC5) - 2 (E2) 3 to 10 kΩ 2 (E2) - 3 (VC5) 3 to 10 kΩ 3 (VC5) - 1 (IB) Below 0.5 kΩ 1 (IB) - 3 (VC5) Below 0.5 kΩ 2 (E2) - 1 (IB) 3 to 10 kΩ 1 (IB) - 2 (E2) 3 to 10 kΩ
If the results are not as specified, replace the battery current sensor assembly.
LEXUS IS250, IS220d / GSE20 ALE20