INSPECT AIR INLET CONTROL SERVO MOTOR (for Automatic Air Conditioning System)
INSPECT AIR INLET CONTROL SERVO MOTOR (for Manual Air Conditioning System)
Air Inlet Control Servo Motor -- Inspection |
1. INSPECT AIR INLET CONTROL SERVO MOTOR (for Automatic Air Conditioning System) |
Inspect the servo motor operation.
Connect the positive (+) lead from the battery to terminal 4 and negative (-) lead to terminal 5, and then check that the arm turns to the "FRESH" side smoothly.
Connect the positive (+) lead from the battery to terminal 5 and negative (-) lead to terminal 4, and then check that the arm turns to the "RECIRCULATION" side smoothly.
If the operation is not as specified, replace the air inlet control servo motor.
![]() |
2. INSPECT AIR INLET CONTROL SERVO MOTOR (for Manual Air Conditioning System) |
Inspect the servo motor operation.
Connect the positive (+) lead from the battery to terminal 5 and negative (-) lead to terminal 1, and then check that the arm turns to the "FRESH" side smoothly.
Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 5, and then check that the arm turns to the "RECIRCULATION" side smoothly. if the operation is not as specified, replaced the air inlet servo motor.
![]() |