Air Conditioning System (For Automatic Air Conditioning System) Air Conditioning Control Panel Does Not Operate
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND)
CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY)
CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL)
REPLACE AIR CONDITIONING CONTROL ASSEMBLY
AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) - Air Conditioning Control Panel does not Operate |
DESCRIPTION
This circuit consists of the air conditioning control and the air conditioning amplifier. When the air conditioning control is operated, signals are transmitted to the air conditioning amplifier through the LIN communication system.If the LIN communication system malfunctions, the air conditioning amplifier does not operate even if the air conditioning control is operated.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BODY GROUND) |
Disconnect the air conditioning control assembly connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Specified Condition
|
E26-7 (GND) - Body ground
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
2.CHECK WIRE HARNESS (AIR CONDITIONING CONTROL ASSEMBLY - BATTERY) |
Disconnect the E26 air conditioning control assembly connector.
Measure the voltage of the wire harness side connector.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E26-7 (GND) - E26-2 (IG+)
| Ignition switch on (IG)
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
3.CHECK WIRE HARNESS (AIR CONDITIONING AMPLIFIER - AIR CONDITIONING CONTROL) |
Disconnect the E26 control connector.
Disconnect the E41 amplifier connector.
Measure the resistance of the wire harness side connector.
- Standard resistance:
Tester Connection
| Specified Condition
|
E41-37 (LIN1) - E26-11 (LIN1)
| Below 1 Ω
|
| REPAIR OR REPLACE HARNESS AND CONNECTOR |
|
|
4.REPLACE AIR CONDITIONING CONTROL ASSEMBLY |
Replace the air conditioning control with a new or properly functioning one.
Operate the air conditioning control to check that it functions properly.
- Result:
Result
| Proceed to
|
Air conditioning control malfunctions
| A
|
Air conditioning control functions properly
| B
|
| END (AIR CONDITIONING CONTROL ASSEMBLY IS FAULTY) |
|
|
A |
|
|
|
REPLACE AIR CONDITIONING AMPLIFIER |
|