K111F Cvt. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
INSPECT SHIFT LOCK CONTROL ECU
INSPECT TRANSMISSION CONTROL SWITCH
INSPECT SHIFT LOCK SOLENOID
Shift Lever -- Inspection |
1. INSPECT SHIFT LOCK CONTROL ECU |
Measure the voltage and resistance according to the value(s) in the table below.
- Standard Voltage and Resistance:
Tester Connection
| Condition
| Specified Condition
|
6 (ACC) - 1 (E)
| Ignition switch ON
| 11 to 14 V
|
6 (ACC) - 1 (E)
| Ignition switch ACC
| 11 to 14 V
|
6 (ACC) - 1 (E)
| Ignition switch off
| Below 1 V
|
4 (STP) - 1 (E)
| Brake pedal depressed
| 11 to 14 V
|
4 (STP) - 1 (E)
| Brake pedal released
| Below 1 V
|
5 (KLS+) - 1 (E)
| 1. Ignition switch ACC and shift lever in P
| Below 1 V
|
2. Ignition switch ACC and shift lever not in P (Within approx. 1 second)
| 7.5 to 11 V
|
3. Ignition switch ACC and shift lever not in P (After approx. 2 seconds)
| 6 to 9.5 V
|
8 (IG) - 1 (E)
| Ignition switch ON
| 11 to 14 V
|
8 (IG) - 1 (E)
| Ignition switch off
| Below 1 V
|
1 (E) - Body ground
| Always
| Below 1 Ω
|
Text in Illustration*1
| Component with harness connected (Shift Lock Control ECU)
|
- HINT:
- Do not disconnect the shift lever assembly connector.
If the result is not as specified, replace the shift lock control ECU.
2. INSPECT TRANSMISSION CONTROL SWITCH |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3 (IG) - 7 (S)
| Shift lever in M, "+" or "-"
| Below 1 Ω
|
2 (SFTU) - 5 (E)
| Shift lever held in "+" (Up-shift)
| Below 1 Ω
|
1 (SFTD) - 5 (E)
| Shift lever held in "-" (Down-shift)
| Below 1 Ω
|
3 (IG) - 7 (S)
| Shift lever not in M, "+" or "-"
| 10 kΩ or higher
|
2 (SFTU) - 5 (E)
| Shift lever in M
| 10 kΩ or higher
|
1 (SFTD) - 5 (E)
| Shift lever in M
| 10 kΩ or higher
|
Text in Illustration*1
| Component without harness connected (Transmission Control Switch)
|
If the result is not as specified, replace the shift lock control unit assembly.
3. INSPECT SHIFT LOCK SOLENOID |
Disconnect the shift lock solenoid connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
4 (P) - 3 (E2)
| Shift lever in P
| 10 kΩ or higher
|
4 (P) - 3 (E2)
| Shift lever not in P
| Below 1 Ω
|
2 (SLS-) - 1 (SLS+)
| Always
| 112 Ω
|
Text in Illustration*1
| Component without harness connected (Shift Lock Solenoid)
|
If the result is not as specified, replace the shift lock control unit assembly.