Ecm -- Installation |
1. INSTALL ECM |
Install the 2 brackets to the ECM with the 4 screws.
- Torque:
- 3.0 N*m{30 kgf*cm, 27 in.*lbf}
![]() |
Connect the 2 ECM connectors.
- NOTICE:
- When connecting the connector, make sure that dirt, water and other foreign matter does not become stuck between the connector and other part.
Connect the 2 ECM connectors and lower the 2 levers.
- NOTICE:
- Make sure that the 2 levers are securely locked.
![]() |
Install the ECM with the 3 bolts.
- Torque:
- 6.5 N*m{66 kgf*cm, 57 in.*lbf}
![]() |
2. INSTALL AIR CLEANER CASE |
Install the air cleaner case with the 3 bolts.
- Torque:
- 5.0 N*m{51 kgf*cm, 44 in.*lbf}
![]() |
Connect the harness clamp.
3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY |
Install the air cleaner filter element onto the air cleaner case.
Insert the hinge part of the air cleaner cap into the air cleaner case, then hang the 2 hook clamps.
![]() |
Tighten the No. 1 air cleaner hose clamp.
![]() |
Connect the No. 2 ventilation hose to the air cleaner hose.
Connect the 2 wire harness clamps and 2 vacuum hoses.
Connect the VSV (intake air control) connector.
Connect the mass air flow meter connector.
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
5. PERFORM REGISTRATION |
When replacing the ECM, perform the vehicle stability control system recognition in the ECM (RAV4_ACA30 RM00000226C001X.html).
6. RESET MEMORY |
When replacing the ECM, perform the RESET MEMORY procedure (A/T initialization) (RAV4_ACA30 RM000000W7F0ALX.html).