Outer Mirror Switch -- Inspection |
1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Retract Mirror) |
![]() |
Inspect the outer mirror switch.
Select "L" on the left/right adjustment switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 9 (MLV) - 11 (B)
6 (M+) - 12 (E)UP Pressed Below 1 Ω Not pressed 10 kΩ or higher 9 (MLV) - 12 (E)
6 (M+) - 11 (B)DOWN Pressed Below 1 Ω Not pressed 10 kΩ or higher 10 (MLH) - 11 (B)
6 (M+) - 12 (E)LEFT Pressed Below 1 Ω Not pressed 10 kΩ or higher 10 (MLH) - 12 (E)
6 (M+) - 11 (B)RIGHT Pressed Below 1 Ω Not pressed 10 kΩ or higher
Select "R" on the left/right adjustment switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 8 (MRV) - 11 (B)
6 (M+) - 12 (E)UP Pressed Below 1 Ω Not pressed 10 kΩ or higher 8 (MRV) - 12 (E)
6 (M+) - 11 (B)DOWN Pressed Below 1 Ω Not pressed 10 kΩ or higher 7 (MRH) - 11 (B)
6 (M+) - 12 (E)LEFT Pressed Below 1 Ω Not pressed 10 kΩ or higher 7 (MRH) - 12 (E)
6 (M+) - 11 (B)RIGHT Pressed Below 1 Ω Not pressed 10 kΩ or higher
Inspect the switch illumination.
Apply battery voltage between the terminals of the light, and check the operation of the light.- OK:
Measurement Condition Specified Condition Battery positive (+) → Terminal 15 (ILL+)
Battery negative (-) → Terminal 16 (ILL-)Light comes on
Text in Illustration *a Component without harness connected
(Outer Mirror Switch Assembly)
2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Retract Mirror) |
![]() |
Inspect the outer mirror switch.
Select "L" on the left/right adjustment switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 9 (MLV) - 11 (B)
6 (M+) - 12 (E)UP Pressed Below 1 Ω Not pressed 10 kΩ or higher 9 (MLV) - 12 (E)
6 (M+) - 11 (B)DOWN Pressed Below 1 Ω Not pressed 10 kΩ or higher 10 (MLH) - 11 (B)
6 (M+) - 12 (E)LEFT Pressed Below 1 Ω Not pressed 10 kΩ or higher 10 (MLH) - 12 (E)
6 (M+) - 11 (B)RIGHT Pressed Below 1 Ω Not pressed 10 kΩ or higher
Select "R" on the left/right adjustment switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 8 (MRV) - 11 (B)
6 (M+) - 12 (E)UP Pressed Below 1 Ω Not pressed 10 kΩ or higher 8 (MRV) - 12 (E)
6 (M+) - 11 (B)DOWN Pressed Below 1 Ω Not pressed 10 kΩ or higher 7 (MRH) - 11 (B)
6 (M+) - 12 (E)LEFT Pressed Below 1 Ω Not pressed 10 kΩ or higher 7 (MRH) - 12 (E)
6 (M+) - 11 (B)RIGHT Pressed Below 1 Ω Not pressed 10 kΩ or higher
Inspect the retract switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 12 (E) - 14 (MF)
11 (B) - 13 (MR)Pushed in Below 1 Ω 12 (E) - 13 (MR)
11 (B) - 14 (MF)Not pushed in Below 1 Ω
Inspect the switch illumination.
Apply battery voltage between the terminals of the light, and check the operation of the light.- OK:
Measurement Condition Specified Condition Battery positive (+) → Terminal 15 (ILL+)
Battery negative (-) → Terminal 16 (ILL-)Light comes on
Text in Illustration *1 Retract Switch *a Component without harness connected
(Outer Mirror Switch Assembly)