Occupant Detection Sensor -- Inspection |
1. INSPECT SEPARATE TYPE FRONT SEAT CUSHION PAD |
![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 3 More than 147 N (15 kgf, 33.0 lbf) applied to occupant detection sensor Below 100 Ω