Rear Power Seat Control System Rear Power Seat Switch Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK FOLD SEAT CONTROL ECU
INSPECT REAR POWER SEAT SWITCH
CHECK HARNESS AND CONNECTOR (FOLD SEAT CONTROL ECU - REAR POWER SEAT SWITCH)
REAR POWER SEAT CONTROL SYSTEM - Rear Power Seat Switch Circuit |
DESCRIPTION
When the rear power seat switch is operated, a recline signal is sent to the fold seat control ECU. The ECU activates the power seat motor based on the signal from the rear power seat switch.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK FOLD SEAT CONTROL ECU |
Remove the fold seat control ECU with its connectors still connected (LandCruiser RM0000045DH00EX.html).
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for LH sideTester Connection
| Condition
| Specified Condition
|
d1-12 (RCLF) - Body ground
| Always
| 11 to 14 V
|
Rear power seat switch LH forward
| Below 1 V
|
d1-13 (RCLR) - Body ground
| Always
| 11 to 14 V
|
Rear power seat switch LH backward
| Below 1 V
|
RH sideTester Connection
| Condition
| Specified Condition
|
c1-12 (RCLF) - Body ground
| Always
| 11 to 14 V
|
Rear power seat switch RH forward
| Below 1 V
|
c1-13 (RCLR) - Body ground
| Always
| 11 to 14 V
|
Rear power seat switch RH backward
| Below 1 V
|
Text in Illustration*A
| for LH Side
|
*B
| for RH Side
|
*a
| Component with harness connected (Fold Seat Control ECU)
|
2.INSPECT REAR POWER SEAT SWITCH |
Remove the rear power seat switch (LandCruiser RM0000045DM00EX.html).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
4 (FWD) - 6 (E)
| Always
| 10 kΩ or higher
|
Rear power seat switch forward
| Below 1 Ω
|
5 (BACK) - 6 (E)
| Always
| 10 kΩ or higher
|
Rear power seat switch backward
| Below 1 Ω
|
3.CHECK HARNESS AND CONNECTOR (FOLD SEAT CONTROL ECU - REAR POWER SEAT SWITCH) |
- *1: for LH Side
- *2: for RH Side
Disconnect the d1*1 or c1*2 ECU connector.
Disconnect the R11*1 or Q10*2 switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LH SideTester Connection
| Condition
| Specified Condition
|
d1-12 (RCLF) - R11-4 (FWD)
| Always
| Below 1 Ω
|
d1-12 (RCLF) - Body ground
| Always
| 10 kΩ or higher
|
d1-13 (RCLR) - R11-5 (BACK)
| Always
| Below 1 Ω
|
d1-13 (RCLR) - Body ground
| Always
| 10 kΩ or higher
|
for RH SideTester Connection
| Condition
| Specified Condition
|
c1-12 (RCLF) - Q10-4 (FWD)
| Always
| Below 1 Ω
|
c1-12 (RCLF) - Body ground
| Always
| 10 kΩ or higher
|
c1-13 (RCLR) - Q10-5 (BACK)
| Always
| Below 1 Ω
|
c1-13 (RCLR) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|