Charging System Charging Failure


INSPECTION PROCEDURE

CHECK GENERATOR PULLEY WITH CLUTCH (ON-VEHICLE INSPECTION)

CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)

CHARGING SYSTEM - Charging Failure


INSPECTION PROCEDURE

1.CHECK GENERATOR PULLEY WITH CLUTCH (ON-VEHICLE INSPECTION)
  1. Start the engine and visually check if the fan of the generator rotor assembly located inside the generator assembly is operating.

    OK:
    The fan of the generator rotor assembly is operating.


NG
REPLACE GENERATOR PULLEY WITH CLUTCH (LandCruiser RM0000017AW00LX.html)
OK


2.CHECK GENERATOR PULLEY WITH CLUTCH (UNIT INSPECTION)
  1. Remove the generator assembly (LandCruiser RM0000017AV00MX.html).

  1. Check the installation condition of the generator pulley cap.

    OK:
    The generator pulley cap is not loose or missing.
  1. Check for grease leaks (for wet pulley) or particle formation due to friction (for dry pulley).

    OK:
    No grease leaks (for wet pulley) or large build-up of particles (for dry pulley).
  1. Check the generator pulley with clutch for misalignment (interference with the generator assembly).

    OK:
    The generator pulley with clutch is correctly aligned (no interference with the generator assembly).


    Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155
  1. Turn the generator pulley with clutch clockwise and counterclockwise by hand and check for noise.

    OK:
    Noise does not occur when turned in both directions.
  1. Turn the generator pulley with clutch clockwise and counterclockwise by hand and visually check for runout.

    OK:
    The generator pulley with clutch does not have runout.


    Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155
  1. Using a screwdriver, hold the fan of the generator rotor assembly located inside the generator assembly in place and check that the generator with clutch pulley locks when turned clockwise and turns freely when turned counterclockwise.

OK:
The generator pulley with clutch locks when turned clockwise and turns freely when turned counterclockwise.


NG
REPLACE GENERATOR PULLEY WITH CLUTCH (LandCruiser RM0000017AW00LX.html)
OK

REPAIR OR REPLACE GENERATOR ASSEMBLY (LandCruiser RM0000017AW00LX.html)